Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Teresa Torzicky"'
Autor:
Stefan Zotter, Richard Haindl, Bernhard Baumann, Michael Pircher, Christoph K. Hitzenberger, Wolfgang Trasischker, Teresa Torzicky
Publikováno v:
Biomedical Optics Express
We present a newly developed single mode fiber based swept source polarization sensitive optical coherence tomography system using a single input state at 1040 nm. Two non-polarizing fiber based beam splitters are combined to form a Mach-Zehnder inte
Autor:
Teresa Torzicky, Wolfgang Trasischker, Mitsuro Sugita, Bernhard Baumann, Michael Pircher, Christoph K. Hitzenberger, Stefan Zotter
Publikováno v:
Biomedical Optics 2014.
We present a fiber based PS-OCT system featuring a swept source at 1040 nm with a circular input state and an A-scan rate of 100 kHz. In vivo human retina images are presented.
Autor:
Wolfgang, Trasischker, René M, Werkmeister, Stefan, Zotter, Bernhard, Baumann, Teresa, Torzicky, Michael, Pircher, Christoph K, Hitzenberger
Publikováno v:
Journal of biomedical optics. 18(11)
We developed a three-beam Doppler optical coherence tomography (OCT) system that enables measurement of the velocity vector of moving particles in three-dimensions (3-D). The spatial orientation as well as the magnitude of motion can be determined wi
Autor:
Sebastian Marschall, Peter Andersen, Stefan Zotter, Marco Bonesi, Thomas Klein, Wolfgang Trasischker, Benjamin R. Biedermann, Bernhard Baumann, Wolfgang Wieser, Teresa Torzicky, Robert Huber, Michael Pircher, Erich Götzinger, Christoph K. Hitzenberger
Publikováno v:
Torzicky, T, Marschall, S, Pircher, M, Baumann, B, Bonesi, M, Zotter, S, Götzinger, E, Trasischker, W, Klein, T, Wieser, W, Biedermann, B, Huber, R, Andersen, P E & Hitzenberger, C K 2013, ' Retinal polarization-sensitive optical coherence tomography at 1060 nm with 350 kHz A-scan rate using an Fourier domain mode locked laser ', Journal of Biomedical Optics, vol. 18, no. 2, pp. 26008 . https://doi.org/10.1117/1.JBO.18.2.026008
Journal of Biomedical Optics; Vol 18
Journal of Biomedical Optics; Vol 18
We present a novel, high-speed, polarization-sensitive, optical coherence tomography set-up for retinal imaging operating at a central wavelength of 1060 nm which was tested for in vivo imaging in healthy human volunteers. We use the system in combin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b1fe11678631ae22ce0ff6fe1ea4a56d
https://orbit.dtu.dk/en/publications/7787f7e3-f744-45b4-b0e2-e83b5c047974
https://orbit.dtu.dk/en/publications/7787f7e3-f744-45b4-b0e2-e83b5c047974
Autor:
Michael Pircher, Christoph K. Hitzenberger, Julia S. Kroisamer, Teresa Torzicky, Erich Götzinger, Stefan Zotter, Hirofumi Yoshida, Futoshi Hirose, Clemens Vass, Stephan Holzer, Ursula Schmidt-Erfurth
Publikováno v:
Investigative ophthalmologyvisual science. 54(1)
PURPOSE We presented a novel polarization sensitive optical coherence tomography (PS-OCT) system for measuring retinal nerve fiber layer (RNFL) birefringence, retardation, and thickness, and report on the repeatability of acquiring these quantities.
Autor:
Robert Huber, Stefan Zotter, Peter Andersen, Marco Bonesi, Teresa Torzicky, Christian Pedersen, Michael Pircher, Christoph K. Hitzenberger, Sebastian Marschall, Wolfgang Wieser, Benjamin R. Biedermann, Thomas Klein, Erich Götzinger
Publikováno v:
SPIE Proceedings.
Optical coherence tomography (OCT) in the 1060nm range is interesting for in vivo imaging of the human posterior eye segment (retina, choroid, sclera), as it permits a long penetration depth. Complementary to structural images, polarization-sensitive
Autor:
Teresa Torzicky, Stefan Zotter, Michael Pircher, Marco Bonesi, Christoph K. Hitzenberger, Erich Götzinger
Publikováno v:
Optometry and Vision Science; Vol 89
PURPOSE To demonstrate the ability of a new high-speed polarization-sensitive optical coherence tomography (PS-OCT) system for retinal imaging at 1040 nm. METHODS A new polarization-sensitive swept source OCT system in the 1 μm wavelength range is u
Autor:
Teresa Torzicky, Christian Pedersen, Thomas Klein, Peter Andersen, Wolfgang Wieser, Sebastian Marschall, Michael Pircher, Christoph K. Hitzenberger, Robert Huber, Benjamin R. Biedermann
Publikováno v:
SPIE Proceedings.
Optical coherence tomography (OCT) in the 1060nm range is interesting for in vivo imaging of the human posterior eye segment (retina, choroid, sclera) due to low absorption in water and deep penetration into the tissue. Rapidly tunable light sources,
Autor:
Teresa Torzicky, Erich Götzinger, Ursula Schmidt-Erfurth, Matthias Bolz, Stefan Zotter, Michael Pircher, Philipp Roberts, Christoph K. Hitzenberger, Ferdinand Georg Schlanitz
Publikováno v:
Scopus-Elsevier
We used a fiber based polarization sensitive spectral domain optical coherence tomography system, using two CMOS line scan cameras to image the lens of healthy volunteers and Cataract patients.
Autor:
Hirofumi Yoshida, Stefan Zotter, Ursula Schmidt-Erfurth, Clemens Vass, Teresa Torzicky, Erich Götzinger, Futoshi Hirose, Philipp Roberts, Michael Pircher, Christoph K. Hitzenberger
Publikováno v:
Scopus-Elsevier
We present a newly developed high-speed, wide-field polarization sensitive spectral domain OCT system for measuring retardation, birefringence and retinal nerve fiber layer thickness in healthy and glaucoma eyes.