Zobrazeno 1 - 10
of 93
pro vyhledávání: '"Tayler, Michael C. D."'
Autor:
Barskiy, Danila A., Blanchard, John W., Budker, Dmitry, Eills, James, Pustelny, Szymon, Sheberstov, Kirill F., Tayler, Michael C. D., Trabesinger, Andreas H.
Zero and ultralow-field nuclear magnetic resonance (ZULF NMR) is an NMR modality where experiments are performed in fields at which spin-spin interactions within molecules and materials are stronger than Zeeman interactions. This typically occurs at
Externí odkaz:
http://arxiv.org/abs/2409.09048
Autor:
Raghavan, Harini, Tayler, Michael C. D., Mouloudakis, Kostas, Rae, Rachel, Lähteenmäki, Sami, Zetter, Rasmus, Laine, Petteri, Haesler, Jacques, Balet, Laurent, Overstolz, Thomas, Karlen, Sylvain, Mitchell, Morgan W.
We describe micro-fabricated rubidium vapor cells with integrated temperature-control functionality and demonstrate their suitability for use in miniaturized ultra-sensitive magnetometers. These functionalized vapor cells (FVCs) embody a dual-chamber
Externí odkaz:
http://arxiv.org/abs/2405.10715
Autor:
Zanoni, Andrea, Mouloudakis, Kostas, Tayler, Michael C. D., Corrielli, Giacomo, Osellame, Roberto, Mitchell, Morgan W., Lucivero, Vito Giovanni
We demonstrate a sensitive optically-pumped magnetometer using rubidium vapor and 0.75 amg of nitrogen buffer gas in a sub-mm-width sensing channel excavated by femtosecond laser writing followed by chemical etching. The channel is buried less than 1
Externí odkaz:
http://arxiv.org/abs/2404.14345
Hyperpolarized nuclear spins in molecules exhibit high magnetization that is unachievable by classical polarization techniques, making them widely used as sensors in physics, chemistry, and medicine. The state of a hyperpolarized material, however, i
Externí odkaz:
http://arxiv.org/abs/2402.10766
Autor:
Zanoni, Andrea, Mouloudakis, Kostas, Tayler, Michael C. D., Corrielli, Giacomo, Osellame, Roberto, Mitchell, Morgan W., Lucivero, Vito Giovanni
Publikováno v:
Journal of Applied Physics; 10/14/2024, Vol. 136 Issue 14, p1-6, 6p
We discuss procedures for error-tolerant spin control in environments that permit transient, large-angle reorientation of magnetic bias field. Short sequences of pulsed, non-resonant magnetic field pulses in a laboratory-frame meridional plane are de
Externí odkaz:
http://arxiv.org/abs/2206.12025
Autor:
Tayler, Michael C. D., Mouloudakis, Kostas, Zetter, Rasmus, Hunter, Dominic, Lucivero, Vito G., Bodenstedt, Sven, Parkkonen, Lauri, Mitchell, Morgan W.
Publikováno v:
Physical Review Applied 18, 014036 -- Published 15 July 2022
Atomic spin sensors offer precision measurements using compact, microfabricated packages, placing them in a competitive position for both market and research applications. Performance of these sensors such as dynamic range may be enhanced through mag
Externí odkaz:
http://arxiv.org/abs/2204.01370
We demonstrate a method to quantify and manipulate nuclear spin decoherence mechanisms that are active in zero to ultralow magnetic fields. These include: (i) non-adiabatic switching of spin quantization axis, due to residual background fields; (ii)
Externí odkaz:
http://arxiv.org/abs/2112.08536
Autor:
Tayler, Michael C. D., Theis, Thomas, Sjolander, Tobias F., Blanchard, John W., Kentner, Arne, Pustelny, Szymon, Pines, Alexander, Budker, Dmitry
We review instrumentation for nuclear magnetic resonance (NMR) in zero and ultra-low magnetic field (ZULF, below 0.1 $\mu$T) where detection is based on a low-cost, non-cryogenic, spin-exchange relaxation free (SERF) $^{87}$Rb atomic magnetometer. Th
Externí odkaz:
http://arxiv.org/abs/1705.04489
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.