Zobrazeno 1 - 10
of 87
pro vyhledávání: '"Tatsuo Torii"'
Publikováno v:
Journal of the Atomic Energy Society of Japan. 64:17-22
Publikováno v:
IEEE Transactions on Nuclear Science. 67:2203-2208
We developed a Gd2Si2O7 (GPS) scintillator-based alpha imaging detector and demonstrated its effectiveness by evaluating the actual Pu particle and 222Rn progeny. The GPS scintillator plate was prepared by a sintering method. The outer dimensions of
Autor:
Yuki Sato, Tatsuo Torii
Publikováno v:
Nuclear Technology. 206:v-xvi
We, the American Nuclear Society, the Editor and Publisher of Nuclear Technology, have retracted the following article: Yuki Sato & Tatsuo Torii: Visualization and Integration of Images of Radioact...
Autor:
Y. Furuta, Hiroshi Usami, Katsunori Aoki, Katsuya Hoshi, Koji Tsurudome, Yuki Morishita, Tatsuo Torii
Publikováno v:
Radiation Protection Dosimetry. 189:172-181
We developed a remote continuous air monitoring (RCAM) system. The RCAM system consisted of a personal air monitor and a robot. The personal air monitor (poCAMon, SARAD, Germany) had a 400-mm2 ion-injected silicon detector and a membrane air filter w
Autor:
Kazutoshi Shingu, Shingo Ozawa, Kojiro Minemoto, Yuta Terasaka, Makoto Nemoto, Satoshi Tamura, Tatsuo Torii, Yuki Sato
Publikováno v:
Journal of Nuclear Science and Technology. 57:734-744
The Fukushima Daiichi Nuclear Power Station (FDNPS), operated by Tokyo Electric Power Company Holdings, Inc., suffered a meltdown as a result of a large tsunami triggered by the Great East Japan Ea...
Publikováno v:
Journal of the Atomic Energy Society of Japan. 62:645-649
Autor:
Tatsuo Torii, Yukihisa Sanada
Publikováno v:
Behavior of Radionuclides in the Environment III ISBN: 9789811667985
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e5b132984011d488b6e9f85d83c374e5
https://doi.org/10.1007/978-981-16-6799-2_3
https://doi.org/10.1007/978-981-16-6799-2_3
Autor:
Yuki Morishita, Junichi Kaneko, Kenji Izaki, Mitsugu Matsuura, Mikio Higuchi, Ken Tamura, Tatsuo Torii, Tatsuo Yajima
Publikováno v:
Radiation Measurements. 122:115-120
A dust monitor with a silicon surface barrier detector (SSBD) is introduced at a nuclear fuel facility to detect airborne contamination of 238Pu and 239Pu released by past accidents. However, an SSBD frequently produces false alarms, especially in a
Publikováno v:
Journal of Environmental Radioactivity. 192:417-425
Airborne radiation monitoring was conducted in order to evaluate the influence of radionuclides emitted by the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident throughout Japan. Carrying out airborne radiation monitoring using manned and unmann
Autor:
Jun Kataoka, Isao Yoda, Yasuhiro Iwamoto, Masaaki Kaburagi, Makoto Arimoto, Tatsuo Torii, Miho Takabe, Masaki Yoneyama, Yuta Terasaka, Yuki Sato, Koki Sueoka
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 912:115-118
After Fukushima’s nuclear disaster in Japan, the decontamination operation is successfully ongoing, and restrictions from some areas were lifted in April 2017. However, the radiation dose rate in the Fukushima Daiichi Plant is still so high (e.g.,