Zobrazeno 1 - 10
of 26
pro vyhledávání: '"Tat Jin Teo"'
Autor:
Teruyoshi Kume, Yasuhiro Honda, Tat-Jin Teo, Paul G. Yock, Shashidhar Sathyanarayana, Katsuhisa Waseda, Peter J. Fitzgerald, Wenguang Li, Byeong Keuk Kim
Publikováno v:
Catheterization and Cardiovascular Interventions. 81:E173-E177
Objectives: The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. Background: We developed the multifrequency processing method to enhance arterial lumen detectio
Autor:
Peter D. Edmonds, Kurt Sandstrom, Timothy A. Bigelow, Marvin C. Ziskin, John G. Abbott, Charles C. Church, Bruce A. Herman, Kai Erik Thomenius, Tat Jin Teo
Publikováno v:
Journal of Ultrasound in Medicine. 30:714-734
The thermal index (TI) has been used as a relative indicator of thermal risk during diagnostic ultrasound examinations for many years. It is useful in providing feedback to the clinician or sonographer, allowing assessment of relative, potential risk
Autor:
Ronald Hamers, Pim J. de Feijter, Nico Bruining, Tat-Jin Teo, Patrick W. Serruys, Jos R.T.C. Roelandt
Publikováno v:
The International Journal of Cardiovascular Imaging formerly The International Journal of Cardiac Imaging. 20:83-91
Intracoronary ultrasound (ICUS) is often used in studies evaluating new interventional techniques. It is important that quantitative measurements performed with various ICUS imaging equipment and materials are comparable. During evaluation of quantit
Autor:
Kiyoshi Hibi, Tat-Jin Teo, Peter J. Fitzgerald, Paul G. Yock, Heidi N. Bonneau, Xiangmin Zhang, Atsushi Takagi
Publikováno v:
Circulation. 102:1657-1663
Background —Ultra–high-frequency (40- to 50-MHz) intravascular ultrasound (IVUS) improves image quality compared with conventional 20- to 30-MHz IVUS. However, as the frequency of IVUS increases, high-intensity backscatter from blood components m
Autor:
Tat-Jin Teo
Publikováno v:
2010 IEEE International Ultrasonics Symposium.
Different implementations of the IVUS technologies are reviewed. Material, fabrication techniques and clinical applications are discussed.
Publikováno v:
2008 IEEE Ultrasonics Symposium.
The need to further improve the spatial resolution of intravascular ultrasound (IVUS) may drive the transducer center frequency even higher than the current 40 MHz range. Using a higher frequency results in stronger scattering echoes from the blood a
Autor:
Tat-Jin Teo
Publikováno v:
IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 45(1)
One common approximation for a field point located in the far field of the transducer is to trapezoidally-shaped function to approximate the true spatial impulse response. A quadrilaterally shaped function is proposed here. The quadrilaterally shaped
Autor:
Nico, Bruining, Ronald, Hamers, Tat-Jin, Teo, Pim J, de Feijter, Patrick W, Serruys, Jos R T C, Roelandt
Publikováno v:
The international journal of cardiovascular imaging. 20(2)
Intracoronary ultrasound (ICUS) is often used in studies evaluating new interventional techniques. It is important that quantitative measurements performed with various ICUS imaging equipment and materials are comparable. During evaluation of quantit
Autor:
Tat Jin Teo
Publikováno v:
Vascular Ultrasound ISBN: 9784431680031
A description of Intra Vascular UltraSound (IVUS) imaging is provided in this chapter. Section 1 describes and compares the solid state versus the mechanical implementation of IVUS. Section 2 describes the current performance capability attainable in
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::fe5cb4e5594a1e7029c2af5726f350e6
https://doi.org/10.1007/978-4-431-67871-7_5
https://doi.org/10.1007/978-4-431-67871-7_5
Autor:
Tat-Jin Teo, John M. Reid
Publikováno v:
The Journal of the Acoustical Society of America. 92:1440-1442
The method of backpropagation is used to estimate the range between two planar surfaces. This method is shown to be more tolerant in a noisy environment than another method that uses the spatial derivative of the measured wave field to estimate the r