Zobrazeno 1 - 10
of 117
pro vyhledávání: '"Takehiro YAMAKOSHI"'
Publikováno v:
Scientific Reports, Vol 12, Iss 1, Pp 1-11 (2022)
Abstract The flow-mediated dilation (FMD) test is commonly utilized and is the only technique for the assessment of vascular endothelial cell function. With this test, the augmentation of a brachial artery diameter following reactive hyperemia is mea
Externí odkaz:
https://doaj.org/article/72812c98b55741c9aff475b4352c627b
Publikováno v:
PeerJ, Vol 9, p e11479 (2021)
Background Although cuff-sphygmomanometry is used worldwide in medical and healthcare fields, it is a fact that the use of an occlusive cuff to obtain blood pressure (BP) is troublesome and inconvenient. There have therefore been on-going efforts to
Externí odkaz:
https://doaj.org/article/aae4b57de8e54f8fb16821e5de59d1d4
Publikováno v:
Scientific Reports, Vol 8, Iss 1, Pp 1-9 (2018)
Abstract Cuffless blood pressure (BP) measurement is an all-inclusive term for a method that aims to measure BP without using a cuff. Recent cuffless technology has made it possible to estimate BP with reasonable accuracy. However, mainstream methods
Externí odkaz:
https://doaj.org/article/54971ba423b64abd9dc2618e1638aae2
Publikováno v:
Medical & Biological Engineering & Computing. 59:1585-1596
Noninvasive and convenient measurement of vascular stiffness is of considerable importance for early detection and treatment of arteriosclerosis. Volume elastic modulus ( $${E}_{{v}}$$ ) is one of representative measures reflecting effective vascular
Publikováno v:
Journal of Biomechanical Science and Engineering, Vol 4, Iss 3, Pp 443-455 (2009)
Hip protectors can reduce the incidence of hip fractures. However, low user acceptance and compliance in use remain a major obstacle in the effective use of hip protectors, due to its discomfort and extra effort needed to wear it, etc. A leak-allowed
Externí odkaz:
https://doaj.org/article/3ce1fa120c774968a2570c75a0dbcc99
Autor:
Takehiro Yamakoshi, Jihyoung Lee, Kenta Matsumura, Yasuhiro Yamakoshi, Peter Rolfe, Daiki Kiyohara, Ken-ichi Yamakoshi
Publikováno v:
PLoS ONE, Vol 10, Iss 12, p e0143506 (2015)
The aim of this study was to compare conventional photoplethysmography (PPG) in a finger with PPG using an integrating sphere (ISPPG) to enhance scattered light collection. Two representative wavelengths were used; 1160 nm, a window through the absor
Externí odkaz:
https://doaj.org/article/d95d0ee56232459aa8434f3bb1bc2af7
Publikováno v:
PLoS ONE, Vol 9, Iss 3, p e91205 (2014)
Recent progress in information and communication technologies has made it possible to measure heart rate (HR) and normalized pulse volume (NPV), which are important physiological indices, using only a smartphone. This has been achieved with reflectio
Externí odkaz:
https://doaj.org/article/2ca431e13f3c4858bf88152107a78102
Publikováno v:
PeerJ, Vol 9, p e11479 (2021)
PeerJ
PeerJ
Background Although cuff-sphygmomanometry is used worldwide in medical and healthcare fields, it is a fact that the use of an occlusive cuff to obtain blood pressure (BP) is troublesome and inconvenient. There have therefore been on-going efforts to
Publikováno v:
Japanese Psychological Research. 61:249-261
Publikováno v:
Journal of Psychophysiology. 32:182-190
Abstract. Pulse volume (PV) and its related measures, such as modified normalized pulse volume (mNPV), direct-current component (DC), and pulse rate (PR), derived from the finger-photoplethysmogram (FPPG), are useful psychophysiological measures. Alt