Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Takashi Sunohara"'
Autor:
Akihiro C. Yamashita, Toshiki Kakee, Takahisa Ono, Jun Motegi, Satoru Yamaguchi, Takashi Sunohara
Publikováno v:
Membranes, Vol 12, Iss 6, p 624 (2022)
Performance of the dialysis membrane is strongly dependent upon the physicochemical structure of the membrane. The objective of this study is to devise a new in vitro evaluation technique to quantify the physicochemical structures of the membrane. Th
Externí odkaz:
https://doaj.org/article/533b0c45aefb4ab881dc1002cd24aa0c
Publikováno v:
Artificial Organs. 42:1070-1077
Blood-membrane interactions can have a large impact on the performance of hemodialysis membranes, particularly for high flux membranes in which the membrane itself provides very low resistance to solute transport. The objective of this study was to e
Autor:
Kiyoshi Abe, Takashi Sunohara, Satoru Yamaguchi, Takayuki Yamagishi, Satoka Aoyagi, Hideo Iwai
Publikováno v:
Analytical and Bioanalytical Chemistry. 409:6387-6396
Blood adsorption onto the inside surface of hollow fiber dialysis membranes was investigated by means of time-of-flight secondary ion mass spectrometry (TOF-SIMS) and near-field infrared microscopy (NFIR) in order to evaluate the biocompatibility and
Autor:
Xueqing Yu, Roberto Schillaci, Yucai Zhang, Takashi Sunohara, Chih-Hsiung Lee, Zachary O'Brien, Naya Huang, Colin McArthur, Chunxia Wang, Alessandra Spazzoli, Jianxiong Lin, Wei Li, Gabriele Donati, Fei Wang, Nicolò Natali, John Myburgh, Haiping Mao, Kyung Min Kim, Rong Rong, Mahsa Hadidi, Andrea Angeletti, Olga Baraldi, Jin-Bor Chen, Yagui Qiu, Xi Xiong, Johan Mårtensson, Louise Cole, Mauro Ursino, Sun Moon Kim, Anna Laura Croci Chiocchini, Qi Li, Hye-Young Kim, Ben-Chung Cheng, Simon Finfer, Yu-Shu Chien, Jin-Gang Zhu, Jie Zhang, Xiaohong Tang, Alan Cass, Gaetano La Manna, Wei Qin, Qian Zhou, Irene Capelli, Seyed Pouria Motevalian, Tian Tao, Gang Long, Huijie Miao, Wenjuan Zhang, Martin Gallagher, Tae Ryung Kim, Diletta Conte, Soon Kil Kwon, Shay McGuiness, Rinaldo Bellomo, Andrew L. Zydney, Zi Li
Publikováno v:
Blood Purification. 45:151-153
Publikováno v:
Artificial organs. 42(11)
Blood-membrane interactions can have a large impact on the performance of hemodialysis membranes, particularly for high flux membranes in which the membrane itself provides very low resistance to solute transport. The objective of this study was to e
Publikováno v:
Blood purification. 45(1-3)
Aims: The objective of this study was to compare the transport characteristics of highly asymmetric cellulose triacetate (ATA™) membranes with that of both symmetric cellulose triacetate and asymmetric polysulfone membranes. Methods: Data were obta
Autor:
Takashi, Sunohara, Toshiaki, Masuda
Publikováno v:
Contributions to nephrology. 189
Dialysis membranes are often made from synthetic polymers, such as polysulfone. However, membranes made from cellulose triacetate have superior biocompatibility and have been used since the 1980s. On-line hemodiafiltration treatment accompanied by ma
Autor:
Takashi Sunohara, Toshiaki Masuda
Background: Dialysis membranes are often made from synthetic polymers, such as polysulfone. However, membranes made from cellulose triacetate have superior biocompatibility and have been used since the 1980s. On-line hemodiafiltration treatment accom
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::467f24c1e94a921d867515a8051469fd
https://doi.org/10.1159/000451044
https://doi.org/10.1159/000451044
Publikováno v:
KAGAKU KOGAKU RONBUNSHU. 24:195-199
大量液置換型血液浄化療法の1つとして注目を集めているpush/pull血液透析濾過法 (push/pull HDF) の溶質除去特性の解明を目的とし, 水系実験ならびに理論解析を通じ検討した.実験としては, (1
Publikováno v:
membrane. 23:327-333
One of the factors to reduce the performance of a hemodialyzer during clinical treatment is membrane fouling caused by protein adsorption. Highly permeable dialysis membranes recently developed are of asymmetrical structure and the reduction in perme