Publikováno v:
2022 9th International Conference on Condition Monitoring and Diagnosis (CMD).
Publikováno v:
IEEJ Transactions on Electrical and Electronic Engineering. 16:925-931
Publikováno v:
2020 29th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV).
Electrical insulation of a vacuum interrupter (VI) is a composite system composed of vacuum, metal, and solid insulator. Detection of weak points in insulation is important for insulation design of VI. However, solid insulators of VI are mostly made
Publikováno v:
IEEE Transactions on Plasma Science. 47:3384-3391
Vacuum circuit breakers (VCBs) are widely used in the medium voltage class. In VCBs, late breakdowns sometimes occur after the circuit current has been interrupted, and these late breakdowns are thought to be triggered by microparticles. In this pape
Publikováno v:
2020 8th International Conference on Condition Monitoring and Diagnosis (CMD).
In vacuum discharge, we found that the discharge developing time depends only upon the discharge path length in the case of gap discharge, whereas it is in inverse proportion to the square of the discharge inception voltage in the case of surface fla
Autor:
Yuto Kikuchi, Haruki Ejiri, Akiko Kumada, Taiki Donen, Keisuke Abe, Kunihiko Hidaka, Mitsuru Tsukima
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 24:3374-3380
Vacuum circuit breakers are widely used in medium-voltage class. In vacuum circuit breakers, restrikes and non-sustained disruptive discharges sometimes occur after current interruptions. It is said that these late breakdowns are triggered by the mic
Autor:
Haruki Ejiri, Akiko Kumada, Kunihiko Hidaka, Mitsuru Tsukima, Taiki Donen, Sigeyasu Matsuoka, Keisuke Abe
Publikováno v:
IEEJ Transactions on Fundamentals and Materials. 137:95-100
Publikováno v:
Electrical Engineering in Japan.
Publikováno v:
2018 28th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV).
When using vacuum interrupters to switch capacitive current, the degree of insulation between the contacts tends to degrade as the broken welds are formed on the contact by making and opening operation. These broken welds locally enhance the electric
Publikováno v:
2018 28th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV).
Vacuum circuit breakers are widely used in the medium voltage class. In vacuum circuit breakers, late breakdowns sometimes occur after the interruption of current, and these late breakdowns are thought to be triggered by microparticles. In this paper