Zobrazeno 1 - 10
of 56
pro vyhledávání: '"T.T. Veenstra"'
Publikováno v:
Superlattices and microstructures, 35(3-6), 657-668. Academic Press Inc.
The heat transfer performance of a micro-vaporizer has been measured by conventional methods (using temperatures, flow rates, effective power input). The study was carried out for laminar flow in channels (5 mm×3 cm×200 μm) micro-structured with s
Publikováno v:
Chemical Engineering Journal, 101(1-3), 357-365. Elsevier
Heat transfer performances for non-boiling and boiling flow of a micro-vaporizer have been measured by standard methods (temperatures, flow rates, effective power input). The study was carried out for laminar flow (Re
Autor:
Jeroen Wissink, Albert Prak, Miko Elwenspoek, T.T. Veenstra, Han Gardeniers, Richard Mateman, Roald M. Tiggelaar, Remco G.P. Sanders, Albert van den Berg, Erwin Berenschot
Publikováno v:
Sensors and actuators, 92(1-2), 25-36. Elsevier
This paper presents two miniaturized analysis systems for measurement of the ammonia concentration in aqueous solutions. Both systems are based on identical micromachined components. In the first system the components are integrated on one chip, thus
Autor:
A. van den Berg, Roald M. Tiggelaar, T.T. Veenstra, Johannes G.E. Gardeniers, Michael Curt Elwenspoek, Remco G.P. Sanders
Publikováno v:
Talanta, 56(2), 331-339. Elsevier
This paper describes the design, realization and characterization of a micromachined light detection cell. This light detection cell is designed to meet the specifications needed for a micro total analysis system in which ammonia is converted to indo
Autor:
Remco G.P. Sanders, Johannes G.E. Gardeniers, Michael Curt Elwenspoek, A. van den Berg, T.T. Veenstra, Johan W. Berenschot
Publikováno v:
Journal of the Electrochemical Society, 148(2), G68-G72. The Electrochemical Society Inc.
Membrane micropump chambers of 11 mm diam with virtually zero dead volume were realized using selective anodic bonding. The selective bonding was achieved with less than 1 nm thick metallic antibonding layers on the glass wafer. Experiments were carr
Publikováno v:
Journal of micromechanics and microengineering, 9(9), 199-202. IOP Publishing Ltd.
A new mixer is designed for mixing a phenolic solution into water. The mixer design is such that it can be easily adjusted for the controlled mixing of a specific compound within a certain time. This paper describes the working principle of the mixer
Autor:
H.J.M. ter Brake, T.T. Veenstra, Srinivas Vanapalli, Henri Jansen, Michael Curt Elwenspoek, Horst Rogalla, Herman J. Holland, G.C.F. Venhorst, P.P.P.M. Lerou, Johannes Faas Burger
Publikováno v:
ISSUE=5;TITLE=5th ESA Micro & Nano Technologies Round Table for Space Applications Statistics 2005
AIP conference proceedings, 823, 1-8. American Institute of Physics
AIP conference proceedings, 823, 1-8. American Institute of Physics
At the University of Twente, research is continued on micro cooling in which cooler components are manufactured by means of micromachining (MEMS). Two projects are carried out in parallel: one on recuperative coolers and one on regenerative coolers.
Autor:
A. van den Berg, T.T. Veenstra
Publisher Summary This chapter discusses a method that has been shown to design a chemical analysis system based on micro-machined components. The main part of designing such a system consists of deriving specifications for all the components involve
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c89624efe482556c1d230691e412028f
https://doi.org/10.1016/s0166-526x(03)80121-6
https://doi.org/10.1016/s0166-526x(03)80121-6
Autor:
Michael Curt Elwenspoek, Johannes G.E. Gardeniers, F.K. Forster, A. van den Berg, T.T. Veenstra, N.R. Sharma
Publikováno v:
Sensors and actuators, 81(2-3), 377-383. Elsevier
Two compliance structures for the use in liquid-based microfluidic systems have been realized with the aid of silicon micromachining. The basic principle is that these structures contain air bubbles that dampen the flow and pressure variations that m
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::80f8d1c847ad197bedbcfa3034e7c7d2
https://research.utwente.nl/en/publications/ba998875-dc28-409c-9b97-c3517f2862cc
https://research.utwente.nl/en/publications/ba998875-dc28-409c-9b97-c3517f2862cc
Autor:
Michael Curt Elwenspoek, A. van den Berg, T.T. Veenstra, Jeroen Wissink, Richard Mateman, Remco G.P. Sanders, Roald M. Tiggelaar, Johannes G.E. Gardeniers, Johan W. Berenschot
Publikováno v:
Micro Total Analysis Systems 2001 ISBN: 9789401038935
University of Twente Research Information (Pure Portal)
University of Twente Research Information (Pure Portal)
Two differently constructed µ-FIA ammonium detection systems have been realized and tested. A monolithic system (Full-Lab-On-A-Chip) shows reproducible measurements for 10 and 20 mM ammonium samples. A modular version of this system could measure am
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::edc1f2cf36dac823bd0043907e513158
https://doi.org/10.1007/978-94-010-1015-3_290
https://doi.org/10.1007/978-94-010-1015-3_290