Zobrazeno 1 - 10
of 18
pro vyhledávání: '"T.R. Ariyaratne"'
Publikováno v:
International Letters of Chemistry, Physics and Astronomy. 38:74-86
The research reported in this paper was conducted to analyze erythrocyte membrane associated proteins (ERMBPs) of some of chronic myeloid leukemia (CML) patients and selected individuals of Sri Lanka employing one dimensional sodium dodecyl sulphate
Publikováno v:
International Journal of Mass Spectrometry and Ion Processes. 152:31-41
Fission fragments from a 252Cf source have been used to study fast heavy ion induced desorption of ions and luminescence in the wavelength region 200–680 nm from samples of Csl, the amino acids valine, isoleucine and tyrosine, and of the peptide su
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Nuclear Instruments and Methods. 156:63-66
A multiwire proportional chamber of novel design has been built to study the feasibility of the chamber to measure high intensity X-rays. The well collimated X-ray beam was made to pass into the chamber parallel to the planes of electrodes and perpen
Publikováno v:
Nuclear Instruments and Methods. 176:523-528
A method has been discussed to measure the drift velocity of electrons in a mixture of argon and nitrogen using a gas scintillation drift chamber. The variations of drift velocities with the drift field and the nitrogen concentration have been invest
Publikováno v:
Nuclear Instruments and Methods. 180:497-501
This paper describes the measurements of charge and light gain in argon-nitrogen mixtures using a gas scintillation proportional counter. The factors studied here which affect light emission, are anode voltage, nitrogen concentration and anode wire d
Publikováno v:
Nuclear Instruments and Methods in Physics Research. 200:341-344
Using a gas mixture of 10% N2 in argon in a gas scintillation counter with a thick wire anode of 400 μm, the energy resolution and the mean pulse height from the photomultiplier were studied at rates up to 10 MHz. A shift of the pulse heigth o only
Publikováno v:
Nuclear Instruments and Methods. 152:579-581
A solid converter consisting of alternate sheets of brass and insulating material has been placed above a multi-wire proportional chamber 1 ). X-rays were converted to photo electrons in this dense material and the electrons drifted through holes in
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.