Zobrazeno 1 - 10
of 47
pro vyhledávání: '"T.H. Mitchell"'
Publikováno v:
IEEE/ASME Transactions on Mechatronics. 15:117-124
The integration of computer-controlled electro-mechanical components in ground vehicle cooling systems can improve coolant temperature regulation and servomotor power consumption. Advanced thermal management systems for internal combustion engines ca
Publikováno v:
IEEE Transactions on Vehicular Technology. 57:127-137
Advanced thermal-management systems for internal combustion engines can improve coolant-temperature regulation and servomotor power consumption by better regulating the combustion process with multiple computer-controlled electromechanical components
Publikováno v:
Journal of Dynamic Systems, Measurement, and Control. 131
The automotive cooling system has unrealized potential to improve internal combustion engine performance through enhanced coolant temperature control and reduced parasitic losses. Advanced automotive thermal management systems use controllable actuat
Autor:
T.H. Mitchell
The SQ Tanks are located on the northwest side of the 221-T plant, in the 200-West Area of the Hanford Reservation. The objective of the survey was to locate subsurface obstructions that may affect the removal of tanks and supporting structures. Base
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c32e42c284f7c607625f2dedb249e1c7
https://doi.org/10.2172/10116870
https://doi.org/10.2172/10116870
Autor:
T.H. Mitchell
A survey was conducted to locate subsurface obstructions that may affect the drilling of three proposed boreholes in the 100K Area. Drill sites with the least likelihood of encountering obstructions were identified by the method of ground-penetrating
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::382a27db46847ac5f03b0dcb3d4469bb
https://doi.org/10.2172/10116117
https://doi.org/10.2172/10116117
Autor:
T.H. Mitchell
The objective of the survey was to locate subsurface obstructions that may affect the drilling of proposed borehole, 199-K-107A, located about 100 ft northwest of the 105 KW Building, 100-K Area. Based upon the results of the survey, possible drill s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::cd05e515ac4754b75782138a62e02379
https://doi.org/10.2172/10105344
https://doi.org/10.2172/10105344
Autor:
T.H. Mitchell
The geophysical investigations identified in this document were conducted by the Westinghouse Hanford Company (WHC) Surface Geophysics Team, Geophysics Group, between October, 1991 and December, 1993. The investigations supported 100-Area activities
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::65357f74ffe2ea32c59eb275d280c47b
https://doi.org/10.2172/10190047
https://doi.org/10.2172/10190047
Autor:
K.A. Bergstrom, T.H. Mitchell
The objective of the electromagnetic survey was to locate subsurface obstructions that may affect the drilling of proposed borehole, 199-K-108A, about 75 ft southeast of the 105 KW Building, 100-K Area. Based upon the results of the survey, possible
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::8b71bb04bb68ff75d8e6375bcddef89f
https://doi.org/10.2172/10170232
https://doi.org/10.2172/10170232
Autor:
T.H. Mitchell
This report describes a geophysical survey performed at the Hanford Reservation. The objective of the survey was to locate subsurface obstructions that may affect cone penetrometer work at site CPT-4, adjacent to and west of borehole 299-W18-252, Fig
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d04b16b4e7136cf495b97447fe4394c5
https://doi.org/10.2172/10193172
https://doi.org/10.2172/10193172