Zobrazeno 1 - 10
of 31
pro vyhledávání: '"T. Wøhni"'
Publikováno v:
Radiation Protection Dosimetry. 147:223-226
To identify the level of compliance with the new radiation protection regulation among Norwegian health care enterprises (HCEs). Totally, 41 HCEs were authorised to use advanced X-ray equipment for medical purposes during 2005-07. Follow-up inspectio
Publikováno v:
Radiation Protection Dosimetry. 113:392-395
The Norwegian Radiation Protection Authority has performed measurements of finger doses to nuclear medicine staff exposed to 99Tc(m), researchers handling 32P, surgeons performing X-ray guided orthopaedic surgery and surgeons and radiologists perform
Autor:
Michael Bailey, K. Henrichs, Y. Nakamura, G. M. Kendall, J. Inaba, A. R. Reddy, R. A. Guilmette, J. Piechowski, Darien Taylor, A. Bouville, A. Kaul, G. Dietze, Luiz Bertelli, Richard W. Leggett, A. W. Phipps, Herwig G. Paretzke, Frances A. Fry, J. L. Lipsztein, François Paquet, F.T. Cross, Christian Streffer, Timothy Fell, O. Hoffman, M. L. Perrin, T. Dillman, V. Berkovski, P. G. Beau, J.W. Stather, R. W. Leggett, Anthony C. James, A. Birchall, J. C. Barton, John Harrison, X. Chen, B. B. Boecker, M. Cristy, R. H. Thomas, V. S. Repin, H. Métivier, Keith F. Eckerman, Eric Ansoborlo, M. Roy, I. A. Likhtarev, T. Smith, D. Noßke, N. S. Nelson, T. Wøhni, M.R. Sikov, Patricia A. Roth
Publikováno v:
Annals of the ICRP. 31:7-9
Autor:
T. Wøhni
Publikováno v:
Radiation Protection Dosimetry.
A dosemeter for measuring depth dose profiles in skin from weakly penetrating radiation, utilising carbon loaded LiF pellets embedded in a Mylar phantom has been developed. The purpose of the dosemeter is to assess skin doses at various depths in ord
Publikováno v:
Dentomaxillofacial Radiology. 10:77-84
Absorbed doses to selected organs of the head and neck region from four standard occlusal examinations of the maxilla were determined using TL dosimeters. A standard phantom was used for internal and external exposure measurements. In addition, exter
Autor:
T. Wøhni
Publikováno v:
Radiation Protection Dosimetry. 14:321-323
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.