This chapter addresses the in-service inspection (ISI) and testing of SGs, excluding the tube bundle inspection which is presented in Chapter 16. The discussion will be centered on vertical shell U-tube recirculating evaporators but some techniques m
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::75f851795ad99a96d979104ee55e291f
https://doi.org/10.1016/b978-0-08-100894-2.00017-0
https://doi.org/10.1016/b978-0-08-100894-2.00017-0
Autor:
C.B. Bahn, S. Bakhtiari, L.B. Carroll, I. de Curieres, A. Drexler, J.A. Gorman, M. Hassan, M. Huang, K. Khumsa-Ang, M. Kreider, S. Laroche, S. Majumdar, A. McKay, E.L. Murphy, L. Obrutsky, L. Papp, J. Riznic, J.C. Smith, T. Sollier, C.W. Turner, J. Vacek, Robert D. Varrin, G. White, Z. Zeng
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::67d6fb251c0f64d3b015cad65a3d22bf
https://doi.org/10.1016/b978-0-08-100894-2.09989-1
https://doi.org/10.1016/b978-0-08-100894-2.09989-1
Publikováno v:
AIP Conference Proceedings.
The French Institute for Radioprotection and Nuclear Safety (IRSN) in partnership with CEA, has started in 2009 a program over several years for the validation of CIVA RX module. The aim of this paper is to present preliminary results of CIVA RX tool
Autor:
A. Skarlatos, C. Gilles-Pascaud, G. Pichenot, G. Cattiaux, T. Sollier, Donald O. Thompson, Dale E. Chimenti
Publikováno v:
AIP Conference Proceedings.
A hybrid Volume Integral Method (VIM)—Finite Elements Method (FEM) model for the numerical modeling of eddy current inspection of steam generator (SG) tubes near quadrifoiled tube support plates (TSP) is presented. The coupled approach combines the
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
AIP Conference Proceedings.
In nuclear plants, the inspection of heat exchanger tubes is usually carried out by using eddy current nondestructive testing. A numerical model, based on a volume integral approach using the Green’s dyadic formalism, has been developed, with suppo
Autor:
J.-L. Jarrousse, D. Chambellan, J. L. Lechien, B. Rattoni, B. A. du Chaffaut, C. Bucherie, T. Sollier
Publikováno v:
21st International Conference on Offshore Mechanics and Arctic Engineering, Volume 2.
Bureau Veritas, CEA and IFP studied the feasibility of on-site inspection of metal layers in the upper part of flexible risers (link between seabed and surface) used by the offshore petroleum industry. The upper part of the flexible pipe is currently
Publikováno v:
Review of Progress in Quantitative Nondestructive Evaluation ISBN: 9781461371700
Automatic thresholding methods have always difficulties to stand out in the NDT field as only one malfunction could be harmful. We propose in this article not only an algorithm to automate thresholding but also an algorithm which gives information on
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a144ce54c92a134000d13fcda9472b5c
https://doi.org/10.1007/978-1-4615-4791-4_115
https://doi.org/10.1007/978-1-4615-4791-4_115
Publikováno v:
Review of Progress in Quantitative Nondestructive Evaluation ISBN: 9781461380276
French PWR cooling systems include austenitic/ferritic stainless steel cast elbows. Due to the aging of these components, there is an increasing need for monitoring possible fabrication flaws near the elbow inner and outer surfaces. Various non destr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d75ae6ce49dc4244771d78e5183befa3
https://doi.org/10.1007/978-1-4613-0383-1_109
https://doi.org/10.1007/978-1-4613-0383-1_109
Autor:
J.M. Bordy, F. Bermann, T. Sollier, J. Dhermain, P. Detroussel, J.C. Jaureguy, P. Chassende-Baroz
Publikováno v:
Radiation Protection Dosimetry.
A capture γ ray beam facility is described. The tests and calibrations performed on titanium and nickel target emitted γ rays are presented. This facility is aimed at the calibrations of radioprotection instruments according to the requirements of