Zobrazeno 1 - 6
of 6
pro vyhledávání: '"T. L. Houck"'
Autor:
R. A. Marsh, F. Albert, S. G. Anderson, G. Beer, T. S. Chu, R. R. Cross, G. A. Deis, C. A. Ebbers, D. J. Gibson, T. L. Houck, F. V. Hartemann, C. P. J. Barty, A. Candel, E. N. Jongewaard, Z. Li, C. Limborg-Deprey, A. E. Vlieks, F. Wang, J. W. Wang, F. Zhou, C. Adolphsen, T. O. Raubenheimer
Publikováno v:
Physical Review Special Topics. Accelerators and Beams, Vol 15, Iss 10, p 102001 (2012)
A design for an X-band rf photoinjector that was developed jointly by SLAC National Accelerator Laboratory (SLAC) and Lawrence Livermore National Laboratory (LLNL) is presented. The photoinjector is based around a 5.59 cell rf gun that has state-of-t
Externí odkaz:
https://doaj.org/article/0cccf0760f2b4816b0889e19180da5b3
The design of an inexpensive, small, high bandwidth diagnostic for the study of vacuum insulator flashover is described. The diagnostic is based on the principle of capacitive coupling and is commonly referred to as a D-dot probe due to its sensitivi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c4758d7e38bdc93add0f01f58017e04f
https://doi.org/10.2172/928534
https://doi.org/10.2172/928534
Autor:
T L Houck, R D Speer, J B Javedani, D A Goerz, L. K. Tully, A. D. White, G E Vogtlin, E.J. Lauer
High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delive
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9c01640533002ab1df90613061d07d67
https://doi.org/10.2172/902244
https://doi.org/10.2172/902244
Knowing the electron beam parameters at the exit of an accelerator is critical for several reasons. Foremost is to optimize the application of the beam, which is flash radiography in the case of the FXR accelerator. The beam parameters not only deter
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::14e3007d95af93563af71e349f8536fb
https://doi.org/10.2172/900448
https://doi.org/10.2172/900448
The radiographic goal of the FXR Optimization Project is to generate an x-ray pulse with peak energy of 19 MeV, spot-size of 1.5 mm, a dose of 500 rad, and duration of 60 ns. The electrical objectives are to generate a 3 kA electron-beam and refine o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a0c5c30c393657c9589308b43f5cc839
https://doi.org/10.2172/899421
https://doi.org/10.2172/899421