Zobrazeno 1 - 8
of 8
pro vyhledávání: '"T. Kyle Stoops"'
Publikováno v:
The Journal of Arthroplasty. 37:45-48
The use of highly conforming polyethylene tibial inserts in cruciate-retaining total knee arthroplasty (TKA) often requires posterior cruciate ligament (PCL) release/sacrifice for balancing (CS TKA). The CS TKA relies on the posterior capsule, collat
Autor:
Jeffrey Orr, Andrew Sephien, Miguel A. Diaz, T. Kyle Stoops, Charles Nofsinger, Brian Hamzavi
Publikováno v:
The Knee. 29
Background Hamstring autografts are commonly used for anterior cruciate ligament (ACL) reconstruction. Different folding techniques exist in tripling the semitendinosus. Few anatomical studies exist in evaluating their viscoelastic properties. The pu
Publikováno v:
Clinical Biomechanics. 47:20-26
Distal radius fractures are common musculoskeletal injuries and many can be treated non-operatively with cast immobilization. A thermo-formable brace has been developed for management of such fractures, but no data exist regarding its comparative sta
Autor:
T. Kyle Stoops, Amy A. Bauer, Nicolette M. Clark, Christopher Shoji, Brandon G. Santoni, Francisco A. Schwartz-Fernandes
Publikováno v:
HAND. 12:551-556
Background: Volar plate fixation of distal radius fractures can result in soft tissue injuries. Abnormal contour of the dorsal cortex of the distal radius provides difficulties in discerning screw penetration on standard radiographs. The skyline and
Publikováno v:
Journal of orthopaedic trauma. 33(2)
Objective To compare the efficacy of 2 intertrochanteric (IT) fracture fixation devices in conferring mechanical stability to unstable IT femur fractures. Methods Nine pairs of cadaveric female femurs with a groupwise average bone quality indicative
Autor:
Brandon G. Santoni, David Donohue, T. Kyle Stoops, Gregory Tanner, Miguel A. Diaz, Mark A. Mighell
Publikováno v:
Journal of orthopaedic trauma. 32(6)
Objective To quantify the stability of 3 points of inferiorly directed versus 3 points of superiorly directed locking screw fixation compared with the full contingent of 6 points of locked screw fixation in the treatment of a 3-part proximal humerus
Publikováno v:
Journal of orthopaedic trauma. 31(4)
Objectives It is recommended that the intra-articular component of a supracondylar distal femoral fracture be stabilized by a lag screw to create interfragmental compression. Generally, it is thought that lag screw fixation should precede any positio
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.