Zobrazeno 1 - 10
of 401
pro vyhledávání: '"T. Chinzei"'
Publikováno v:
Sensors and Actuators B: Chemical. 108:772-777
A prospect for the observation of biochemical reaction by surface plasmon resonance (SPR) is discussed. It has been known that reactions can be monitored either by observation of resonance minimum incidence angle, or by observation of reflectance int
Publikováno v:
Sensors and Actuators B: Chemical. 93:468-474
A new chemi-resister type sensor for hydrogen leak detection is suggested. Tungsten trioxide (WO 3 ) with Pt was used as sensing material. The sensor was fabricated by a sol–gel method. Tungstic acid sol with chloroplatinic acid was spread on a qua
Autor:
Koki Takiura, Yusuke Abe, Shinichi Kobayashi, T. Chinzei, Hirokuni Arai, Tomoyuki Yambe, Itsuro Saito, Shin-ichi Nitta, Hiroyuki Hashimoto, Satoyuki Kawano, Takashi Isoyama, Kou Imachi
Publikováno v:
Artificial Organs. 27:73-77
The prototype of the miniature vibrating flow pump (VFP) is developed for the external shunt catheter. The cross-slider mechanism is applied to vibrate the tube, which causes the pumping effect. This mechanism results in successful development of the
Autor:
T. Chinzei, Shinichi Kobayashi, Tomoyuki Yambe, Yusuke Abe, S Mochizuki, Toshiya Ono, Takashi Isoyama, Kou Imachi, Itsuro Saito, Akimasa Kono, Shin-ichi Nitta
Publikováno v:
Journal of Artificial Organs. 4:103-106
A small-sized blood pump is required for a high-performance total artificial heart. From the viewpoint of the implantation, anatomical fitting into the cavity from which the heart has been removed is very important for the design of the total artific
Publikováno v:
IEEE Engineering in Medicine and Biology Magazine. 19:71-76
Skin temperature is determined by blood-flow rate, structure of subcutaneous tissue, and activities of the sympathetic nervous system, which regulate heat dissipation from the body surface. Because of this, we can noninvasively detect distributions o
Autor:
Kiyomi Sugai, T. Chinzei
Publikováno v:
Sen'i Gakkaishi. 52:261-267
Skin temperature, oral temperature and sensation were measured, and fluctuations of skin temperature were investigated by frequency analysis, to examine age-related differences in thermo-regulated response under changing ambient temperature. The subj
Autor:
Y, Abe, T, Chinzei, T, Isoyama, T, Ono, S, Mochizuki, I, Saito, K, Iwasaki, M, Ishimaru, T, Karita, A, Kuono, K, Baba, K, Imachi
Publikováno v:
Artificial Organs. 25:69-71
The undulation pump is a small continuous flow displacement-type blood pump. The undulation pump total artificial heart (UPTAH) is a unique implantable total artificial heart using undulation pumps. An adult female goat weighing 45.8 kg was used for
Autor:
Akimasa Kouno, Iwao Fujimasa, Toshiya Ono, Kaoru Imanishi, T. Chinzei, T. Tago, Kazuhiko Atsumi, T. Yonezawa, Shin-ichiro Niwa, Kunihiko Mabuchi, Yuusuke Abe, Ichiro Sogawa, Koro Yotsuya, T. Nogaki, Kou Imachi
Publikováno v:
THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE. 13:507-510
Autor:
Kou Imachi, T. Chinzei, Toshiya Ono, J. Nonomura, Iwao Fujimasa, Akimasa Kouno, Toshinobu Onomura, Takumi Yonezawa, R. Kusaka, Kunihiko Mabuchi, Yuusuke Abe
Publikováno v:
THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE. 13:421-424
Autor:
Kazuhiko Atsumi, Kou Imachi, Kozo Suma, Yuji Koyama, Takumi Yonezawa, Kunihiko Mabuchi, Iwao Fujimasa, Kaoru Imanishi, Shiroma K, T. Chinzei, Yusuke Abe
Publikováno v: