Zobrazeno 1 - 10
of 52
pro vyhledávání: '"T. Bolognese-Milsztajn"'
Autor:
Giorgio Curzio, B. Lievens, M. Coeck, A. Fiechtner, J.-E. Lillhök, Francesco D'Errico, Helmut Schuhmacher, Filip Vanhavere, Marcel Reginatto, T. Bolognese-Milsztajn, Richard Tanner, M. Boschung, A. Lövefors-Daun, M. Luszik-Bhadra, D. Hallfarth, Lennart Lindborg, V. Lacoste
Ratios of H(p)(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these fa
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5d2010d0e336ae22f6a8bc40681951f7
http://doc.rero.ch/record/293741/files/ncm394.pdf
http://doc.rero.ch/record/293741/files/ncm394.pdf
Autor:
A. Fiechtner, Richard Tanner, Francesco D'Errico, M. Boschung, Giorgio Curzio, J.-E. Lillhök, Helmut Schuhmacher, M. Coeck, Marcel Reginatto, V. Lacoste, T. Bolognese-Milsztajn, M. Luszik-Bhadra, Lennart Lindborg, Filip Vanhavere
Publikováno v:
RADIATION PROTECTION DOSIMETRY
RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4), pp.471-476. ⟨10.1093/rpd/ncm095⟩
RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4), pp.471-476. ⟨10.1093/rpd/ncm095⟩
The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Pre
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a2aed9e7488ea4c8b40060cc19885432
http://doc.rero.ch/record/291903/files/ncm095.pdf
http://doc.rero.ch/record/291903/files/ncm095.pdf
Autor:
Filip Vanhavere, M. Coeck, V. Gressier, J.-E. Kyllönen, C. Molinos, Marcel Reginatto, T. Bolognese-Milsztajn, M. Boschung, D. Derdau, David Bartlett, A. Fiechtner, M. Luszik-Bhadra, Valerio Giusti, Francesco D'Errico, Giorgio Curzio, Lennart Lindborg, V. Lacoste, Helmut Schuhmacher, Richard Tanner, G. Pelcot
EVIDOS ('evaluation of individual dosimetry in mixed neutron and photon radiation fields') is an European Commission (EC)-sponsored project that aims at a significant improvement of radiation protection dosimetry in mixed neutron/photon fields via sp
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4537f10bce4d57907ecabc4d8dfa07ad
http://doc.rero.ch/record/304244/files/nch220.pdf
http://doc.rero.ch/record/304244/files/nch220.pdf
Autor:
A. Lovefors Daun, M. Luszik-Bhadra, B. Lievens, M. Coeck, Filip Vanhavere, D. Derdau, Lennart Lindborg, Giorgio Curzio, M. Boschung, J.-E. Kyllönen, Marcel Reginatto, T. Bolognese-Milsztajn, Richard Tanner, A. Fiechtner, Francesco D'Errico, V. Lacoste, Helmut Schuhmacher
Within the EC project EVIDOS (‘Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields’), different types of active neutron personal dosemeters (and some passive ones) were tested in workplace fields at nuclear installatio
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e106056f70fdaf855986804c9cd64d00
http://doc.rero.ch/record/303544/files/ncm190.pdf
http://doc.rero.ch/record/303544/files/ncm190.pdf
Autor:
M. Coeck, Marcel Reginatto, T. Bolognese-Milsztajn, Richard Tanner, Giorgio Curzio, David Bartlett, V. Lacoste, M. Luszik-Bhadra, M. Boschung, Helmut Schuhmacher, Filip Vanhavere, A. Fiechtner, Francesco D'Errico, Lennart Lindborg
Publikováno v:
Radiation Protection Dosimetry. 124:219-229
Within the EC project EVIDOS, 17 different mixed neutron-photon workplace fields at nuclear facilities (boiling water reactor, pressurised water reactor, research reactor, fuel processing, storage of spent fuel) were characterised using conventional
Publikováno v:
Radiation Protection Dosimetry. 125:261-266
In 2001, the European Radiation Dosimetry Group, EURADOS, started a working group on 'Harmonisation of Individual Monitoring in Europe and the Dissemination of Information on New Techniques in this Field'. Within this group, one of the projects consi
Publikováno v:
Radiation Protection Dosimetry. 112:141-168
In this paper, we will present a first (but not complete) status description of active personal dosemeters (APDs) and their implementation in European countries. In modern radiation protection practices, APDs are becoming absolutely necessary operati
Publikováno v:
Radiation Protection Dosimetry. 96:241-244
Individual neutron dosimetry represents one of the current difficulties in the field of radiological protection of workers. Since March 1999, the regulatory requirements in France for active (i.e. operational) dosimetry have been those of ICRP Public
Publikováno v:
Radiation Protection Dosimetry. 96:245-249
Following the specifications and test methods given by international standards IEC-61526 and ISO 4037, the dosimetry department of the IPSN studied the photon radiation performance of seven recent electronic personal dosemeters: The personal dosimetr
Publikováno v:
Radioprotection. 35:223-230
La dosimetrie individuelle des neutrons constitue une des difficultes actuelles de la radioprotection des travailleurs. La dosimetrie dite active (operationnelle) est reglementaire depuis mars 1999 ; les valeurs des seuils recommandees par la CIPR 60