Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Svein Magne Hellesø"'
Autor:
G. Berg, Magne Runde, Risto Mikkonen, Niklas Magnusson, Arne Nysveen, Svein Magne Hellesø, Asger Bech Abrahamsen
Publikováno v:
Physica. C, Superconductivity
Magnusson, N, Hellesø, S M, Mikkonen, R, Abrahamsen, A B, Runde, M, Berg, G & Nysveen, A 2021, ' Testing of an MgB 2 coil for a wind turbine generator pole ', Physica C: Superconductivity and its Applications, vol. 587, 1353901 . https://doi.org/10.1016/j.physc.2021.1353901
Magnusson, N, Hellesø, S M, Mikkonen, R, Abrahamsen, A B, Runde, M, Berg, G & Nysveen, A 2021, ' Testing of an MgB 2 coil for a wind turbine generator pole ', Physica C: Superconductivity and its Applications, vol. 587, 1353901 . https://doi.org/10.1016/j.physc.2021.1353901
We report on the testing of a 1 m long and 0.5 m wide racetrack coil wound from 4.5 km of MgB2 tape-shaped superconductors with a copper strip soldered to the nickel matrix. The cross-section of the coil corresponds to what is needed for the field wi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2ec806c6710bf196f0f03d28c2239cdd
https://trepo.tuni.fi/handle/10024/133402
https://trepo.tuni.fi/handle/10024/133402
Publikováno v:
CIRED - Open Access Proceedings Journal. 2017:194-197
Publikováno v:
Proceedings of the Nordic Insulation Symposium.
Humidity can enter the insulation system when the outer sheath of a cable becomes damaged. The relative humidity can then increase above a critical value (70 % RH), facilitating initiation and growth of water trees. The purpose of this experimental a
Publikováno v:
Proceedings of the Nordic Insulation Symposium.
High voltage subsea cables are normally sheathed with a metallic water barrier at voltage levels above 36 kV as recommended by the standards (IEC 60840). The main concern with water ingress in power cables is the risk of water tree formation. Water t
Autor:
Arne Nysveen, Patrick King, Niklas Magnusson, Magne Runde, Jan Christian Eliassen, Asger Bech Abrahamsen, Svein Magne Hellesø, Jarle Bjerkli, Lars-Erik Moslatt
Publikováno v:
IEEE transactions on applied superconductivity
Magnusson, N, Eliassen, J C, Abrahamsen, A B, Helleso, S M, Runde, M, Nysveen, A, Moslatt, L-E, Bjerkli, J & King, P 2018, ' Fabrication of a Scaled MgB2 Racetrack Demonstrator Pole for a 10-MW Direct-Drive Wind Turbine Generator ', I E E E Transactions on Applied Superconductivity, vol. 28, no. 4, 5207105 . https://doi.org/10.1109/TASC.2018.2815027
Magnusson, N, Eliassen, J C, Abrahamsen, A B, Helleso, S M, Runde, M, Nysveen, A, Moslatt, L-E, Bjerkli, J & King, P 2018, ' Fabrication of a Scaled MgB2 Racetrack Demonstrator Pole for a 10-MW Direct-Drive Wind Turbine Generator ', I E E E Transactions on Applied Superconductivity, vol. 28, no. 4, 5207105 . https://doi.org/10.1109/TASC.2018.2815027
Field windings made of MgB2 wires or tapes are considered for their potential to reduce volume, weight and cost of large offshore wind turbine generators. To gain experience of how to use this relatively new material in full-scale generators, tests o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ff2a915157b2190c38b203388dbe1aa6
https://hdl.handle.net/11250/2495329
https://hdl.handle.net/11250/2495329
Autor:
Bernhard Müller, Åsmund Ervik, Svein Magne Hellesø, Svend Tollak Munkejord, Torstein Eidsnes Penne
Publikováno v:
International Journal of Multiphase Flow
In this paper we present experimental and numerical studies of the electrohydrodynamic stretching of a sub-millimetre-sized salt water drop, immersed in oil with added non-ionic surfactant, and subjected to a suddenly applied electric field of magnit
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ed3faa3f7d774c0b48b604b33c3a640a
http://arxiv.org/abs/1711.08969
http://arxiv.org/abs/1711.08969
Publikováno v:
Experiments in Fluids
Results are presented concerning the influence of an applied electric field on the coalescence of a water droplet with a much bigger water drop, both drops being immersed in a crude oil. This original study of electrocoalescence in crude oil was perf
The behaviour of a single sub-millimetre-size water drop falling through a viscous oil while subjected to an electric field is of fundamental importance to industrial applications such as crude oil electrocoalescers. Detailed studies, both experiment
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d9ff25ec9105505f1d986331153390ad
http://arxiv.org/abs/1405.0911
http://arxiv.org/abs/1405.0911
Publikováno v:
2012 IEEE International Symposium on Electrical Insulation.
Water treeing is the major aging mechanism in wet-designed cross-linked polyethylene (XLPE) cables causing a reduced lifetime. Several factors affect the initiation and growth of water trees. Without the presence of an electrical field, contaminants
Publikováno v:
Conference Record of the 2008 IEEE International Symposium on Electrical Insulation.
The major aging mechanism in polymeric medium voltage cable insulation is water treeing. Water trees can grow from contaminations and protrusions in the cable insulation when the relative humidity (RH) in the cable insulation exceeds a value of about