Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Surasak Jitprapaikulsarn"'
Autor:
Chantas Mahaisavariya, Surasak Jitprapaikulsarn, Banchong Mahaisavariya, Nattapon Chantarapanich
Publikováno v:
Journal of Orthopaedic Surgery and Research, Vol 19, Iss 1, Pp 1-9 (2024)
Abstract Background Basicervical femoral neck fracture is a rare proximal femur fracture with a high implant failure rate. Biomechanical comparisons between cephalomedullary nails (CMNs) and dynamic hip screws (DHSs) under torsion loading are lacking
Externí odkaz:
https://doaj.org/article/4eeb32d7e73d4a5da691a6afc7026929
Autor:
Surasak Jitprapaikulsarn, Arthit Gromprasit, Kritsada Sukha, Chawanan Patamamongkonchai, Chittawee Jiamton
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 33:1431-1437
The optimal technique and implant for fixation of multifragmentary fractures of the distal humeral shaft remain inconclusive. We describe the use of minimally invasive plate osteosynthesis (MIPO) via posterior approach and extra-articular distal hume
Autor:
Kritsada Sukha, Arthit Gromprasit, Chawanan Patamamongkonchai, Witoon Thremthakanpon, Surasak Jitprapaikulsarn
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 32:505-513
Open proximal tibial fractures accompanied by soft tissue loss are substantially challenging to accomplish both bony consolidation and wound healing. The authors retrospectively delineated the utility of the various forms of the gastrocnemius muscle
Autor:
Chawanan Patamamongkonchai, Nattapon Chantarapanich, Arthit Gromprasit, Surasak Jitprapaikulsarn, Chantas Mahaisavariya
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 31:1179-1192
The optimal surgical management of concurrent cervicotrochanteric and shaft fractures of the femur has not been consensual. The authors investigated the reliability of combined single lag screw and reverse distal femur locking compression plate (LCP-
Autor:
Surasak Jitprapaikulsarn, Kritsada Sukha, Arthit Gromprasit, Witoon Thremthakanpon, Chawanan Patamamongkonchai
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 31:711-718
It is difficult to establish both fracture union and wound healing of open fractures complicated with soft tissue defects of the distal tibia. We describe the simultaneous use of internal fixation and soft tissue coverage by a distally based sural fl
Autor:
Arthit Gromprasit, Witoon Thremthakanpon, Surasak Jitprapaikulsarn, Chawanan Patamamongkonchai, Kriangkamol Benjawongsathien
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 31:413-420
Utilization of combined local muscle flaps for Gustilo type IIIB open tibial fractures has not been clearly delineated. We describe a combination of medial gastrocnemius and hemisoleus flaps for managing open tibial fractures accompanying large or do
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 30:1515-1521
To describe the surgical application of anterior minimally invasive plating osteosynthesis (MIPO) using reversed proximal humerus internal locking system (PHILOS) plate for multifragmentary distal humeral shaft fractures. Twelve patients with distal
Autor:
Surasak Jitprapaikulsarn, Arthit Gromprasit, Chawanan Patamamongkonchai, Witoon Thremthakanpon
Publikováno v:
Acta orthopaedica Belgica. 87(4)
Segmental fractures of the femur are technically difficult to manage by intramedullary nailing, the gold standard treatment. We specifically describe minimally invasive plate osteosynthesis (MIPO) without floating segment fixation for this particular
Dual plating for fixation failure of the distal femur: Finite element analysis and a clinical series
Autor:
Surasak Jitprapaikulsarn, Nattapon Chantarapanich, Arthit Gromprasit, Chantas Mahaisavariya, Kritsada Sukha, Suwichote Chiawchan
Publikováno v:
Medical Engineering & Physics. 111:103926
Autor:
Nattapon Chantarapanich, Surasak Jitprapaikulsarn, Banchong Mahaisavariya, Chantas Mahaisavariya
Publikováno v:
Medical Engineering & Physics. 107:103856
A smaller dimension of the femoral neck in the Asian population may have difficulty placing inverted triangle multiple screws configuration for treatment. Posterior triangle configuration, which is suitable in limited space of the femoral neck, is a