Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Sun-Yeo Mun"'
Publikováno v:
Applied Sciences, Vol 12, Iss 23, p 12278 (2022)
In this study, experiments and numeric studies were conducted to analyze the causes of abnormal behavior in temperature, heat flux, and combustion efficiency that occurred before a compartment fire was converted to the under-ventilated condition. The
Externí odkaz:
https://doaj.org/article/6c6fe983543a4e1dbe6e33427b1b62fc
Publikováno v:
Applied Sciences, Vol 11, Iss 13, p 5942 (2021)
The effects of changes in irradiance level (external heat flux), exhaust flow rate, and hood height on CO and soot yield were examined using a cone calorimeter. Black acrylic, having similar constituents as polymethyl methacrylate, was used as a comb
Externí odkaz:
https://doaj.org/article/ccbeec73edf94bbcb5397ef60fa790e0
Publikováno v:
Fire Science and Engineering. 36:29-37
In this study, measurements and a review of the pyrolysis properties required for fire spread simulations of rigid spray polyurethane foam (SPF) were performed. The change in the mass ratio of the hardener and resin during the foaming of the SPF had
Publikováno v:
Fire Science and Engineering. 36:38-47
The analysis and review of the thermal decomposition properties required for the fire spread simulation of cables composed of multiple materials were performed. Thus, a typical two-step pyrolysis reaction was identified independent of cable type. It
Publikováno v:
Fire Science and Engineering. 34:27-33
Physical quantities such as mass loss rate, heat release rate, and total heat release are often measured through a cone calorimeter (a representative bench-scale apparatus) and are primarily considered as values per unit area. Hence, the uniformity o
Publikováno v:
Fire Science and Engineering. 34:35-42
The accurate prediction of fire detector activation time is required to ensure the reliability of fire modeling during the safety assessment of performance-based fire safety design. The main objective of this study is to determine the activation temp
Autor:
Cheol-Hong Hwang, Sun-Yeo Mun
Publikováno v:
Fire science and engineering. 33:29-36
Publikováno v:
Fire science and engineering. 33:76-84
Autor:
Sun-Yeo Mun, Cheol-Hong Hwang
Publikováno v:
Materials, Vol 13, Iss 1712, p 1712 (2020)
Materials
Volume 13
Issue 7
Materials
Volume 13
Issue 7
Flame retardant cables were investigated using thermo-gravimetric analysis to measure the reference temperature and reference rate required for a fire spread simulation using a Fire Dynamics Simulator (FDS). Sensitivity analysis was also performed to
Publikováno v:
Fire Science and Engineering. 29:34-41
The applicability of plate thermometer (PT), which feature simple installation and low cost, was experimentally examined in steady and unsteady-state fire conditions. An infrared radiation heater and a square burner with C3H8 as fuel were used as hea