Zobrazeno 1 - 10
of 14
pro vyhledávání: '"Stephen L. Monfre"'
Autor:
Robert E. Coifman, Kenneth R. Lutchen, Xiaohe K Xu, Brian P Harvey, Charles E. Forbes, Brian D. Gelbman, Stephen L. Monfre
Publikováno v:
Medical Devices (Auckland, N.Z.)
Xiaohe K Xu,1 Brian P Harvey,2 Kenneth R Lutchen,2 Brian D Gelbman,3 Stephen L Monfre,1 Robert E Coifman,1 Charles E Forbes1 1Feather Sensors, LLC, Millville, NJ 08332, USA; 2Department of Biomedical Engineering, Boston University, Boston, MA 02215,
Publikováno v:
Biochemistry & Physiology: Open Access.
As a device for measuring lung function in pulmonary medicine, we have developed a probe containing a strain gauge housed in a plastic form with two wires that connect to an audio jack, for communication with electronic equipment. This device is prop
Publikováno v:
Clinical Chemistry. 45:1651-1658
Background: Self-monitoring of blood glucose by diabetics is crucial in the reduction of complications related to diabetes. Current monitoring techniques are invasive and painful, and discourage regular use. The aim of this study was to demonstrate t
Publikováno v:
Analytical Chemistry. 68:2987-2995
A novel approach to the transfer of multivariate calibration is proposed. This method is based on the finite impulse response (FIR) filtering of a set of spectra to be transferred, using a spectrum on the target instrument to direct the filtering pro
Publikováno v:
Journal of Near Infrared Spectroscopy. 1:55-62
The near infrared spectroscopic determination of additive levels in polypropylene pellets obtained from two process extruders/pelletisers is described. A quotient-term multiple linear least-squares spectroscopic model was derived that characterises a
Autor:
Stephen L. Monfre, Steven D. Brown
Publikováno v:
Applied Spectroscopy. 46:1699-1710
A new procedure for performing quantitative analysis in the Fourier domain has been developed. The procedure involves the use of a linear, recursive digital filter for the analysis of raw interferogram data from a Fourier transform infrared (FT-IR) s
Publikováno v:
NIR news. 1:14-17
Autor:
Kevin H. Hazen, Timothy L. Ruchti, Thomas B. Blank, Marcy R Makarewicz, Mutua Mattu, Stephen L. Monfre, Alex Lorenz
Publikováno v:
SPIE Proceedings.
Non-invasive blood glucose monitoring has long been proposed as a means for advancing the management of diabetes through increased measurement and control. The use of a near-infrared, NIR, spectroscopy based methodology for noninvasive monitoring has
Publikováno v:
Talanta. 41(3)
A process near-infrared (NIR) spectrophotometer was interfaced directly to a reactor by using a fiber optic bundle interactance immersion probe. This remote sensor configuration enables the production of polyurethanes to be monitored in real-time. A
Publikováno v:
NIR news. 2:10-10