Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Stefan Andreas Meissner"'
Publikováno v:
Foot and Ankle Surgery. 28:1366-1371
The aim of the study was to assess the 5-year-follow-up (5FU) after Autologous Matrix Induced Chondrogenesis plus Peripheral Blood Concentrate (AMIC+PBC) in chondral defects at the first metatarsophalangeal joint (MTP1).In a prospective consecutive n
Publikováno v:
Footankle international. 44(1)
Background: The aim of this study was to compare outcome (clinical, patient-reported outcome measures, radiologic, joint motion and pedographic) of total joint replacement with Roto-Glide (RG) and arthrodesis (A) for severe osteoarthritis of the firs
Publikováno v:
Fuß & Sprunggelenk. 18:217-226
Summary Background The aim of the study was to compare matrix-associated stem cell transplantation (MAST) with autologous matrix induced chondrogenesis plus peripheral blood concentrate (AMIC+PBC) in chondral defects at the first metatarsophalangeal
Publikováno v:
Foot and Ankle Surgery. 26:669-675
Background The aim of the study was to compare Matrix-Associated Stem Cell Transplantation (MAST) with Autologous Matrix Induced Chondrogenesis plus Peripheral Blood Concentrate (AMIC + PBC) in Chondral Lesions at the Ankle. Methods In a matched-pati
Autor:
Regina Schilke, Issam Naef, Fabian Duerr, Stefan Zech, Stefan Andreas Meissner, Martinus Richter
Publikováno v:
Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 28(7)
Purpose of this study was to compare automatic software-based angular measurement (AM, Autometrics, Curvebeam, Warrington, PA, USA) with previously validated measurement by hand (MBH) regarding angle values and time spent for the investigator for Wei
Publikováno v:
Foot & Ankle Orthopaedics
Foot & Ankle Orthopaedics, Vol 5 (2020)
Foot & Ankle Orthopaedics, Vol 5 (2020)
Category: Basic Sciences/Biologics Introduction/Purpose: Weight-bearing CT (WBCT) has been proven to allow for more precise and valid measurement of bone position (angles) than conventional weight-bearing radiographs (R) and conventional CT without w
Publikováno v:
Foot and Ankle Surgery. 23:195-200
The aim of the study was to assess the 2-year-follow-up of matrix-associated stem cell transplantation (MAST) in chondral defects of the 1st metatarsophalangeal joint (MTPJ). In a prospective consecutive non-controlled clinical follow-up study, 20 pa
Publikováno v:
Foot & Ankle Orthopaedics
Foot & Ankle Orthopaedics, Vol 4 (2019)
Foot & Ankle Orthopaedics, Vol 4 (2019)
Category: Midfoot/Forefoot Introduction/Purpose: Matrix-associated stem cell transplantation (MAST) has shown good short-term results for treatment of chondral defects at first metatarsophalangeal joint (MTP1). The aim of the study was to assess mid-
Publikováno v:
Footankle international. 39(3)
Background: A customized pedography sensor (Pliance; Novel, Munich, Germany) was inserted into a pedCAT (Curvebeam, Warrington, PA). The aim of this study was to analyze the relative position of the anatomical foot center (FC) and the pedographic cen
Publikováno v:
Foot & Ankle Orthopaedics, Vol 2 (2017)
Category: Basic Sciences/Biologics Introduction/Purpose: PedCAT (Curvebeam, Warrington, USA) is a technology for 3D-imaging with full weight bearing which has been proven to exactly visualize the 3D-bone position. Center of gravity (COG) and Foot Cen