Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Stanford E. Sumida"'
Autor:
Susan E. McCormick, Geoffrey C. Jiranek, Shirley L. Raltz, Drew B. Schembre, David J. Patterson, David B. Drajpuch, Michael Gluck, Stanford E. Sumida, Martin D. Gelfand, Richard A. Kozarek, John J. Brandabur, Ball Tj, Darlene K. Moran, Fouad M. Attia, S K Roach, James E. Bredfeldt
Publikováno v:
Gastrointestinal Endoscopy. 53:747-750
Background: Recent studies have indicated that reusable biopsy forceps remain contaminated after reprocessing and can only be used a mean of 12 to 25 times without malfunction. Because this contradicts traditional endoscopic practice, our study inves
Publikováno v:
American Journal of Gastroenterology. 94:139-143
Argon plasma coagulation probes (APC) are currently marketed in the United States as single-use items, and may constitute a significant per-procedure expense. It is unknown whether these probes can be sterilized after endoscopic use and if electrical
Publikováno v:
Gastrointestinal Endoscopy. 47:377-381
Background : Previous studies have shown that pathogens may persist within bacterial biofilms in endoscope accessory channels despite high-level disinfection. Breaching the gastrointestinal mucosa with biopsy forceps contaminated at time of passage h
Autor:
Ball Tj, Irizarry Dl, John J. Brandabur, Stanford E. Sumida, Drajpuch De, Shirley L. Raltz, Michael Gluck, David J. Patterson, S K Roach, Richard A. Kozarek
Publikováno v:
Endoscopy. 33(5)
Background and Study Aims: Therapeutic endoscopic retrograde cholangiopancreatography (ERCP) has been deemed to be a cost-prohibitive procedure, based upon the cumulative costs of one-time-use accessories and current reimbursement plans. One-time-use
Autor:
Shirley L. Raltz, Shiro Urayama, Linda D. Merriam, Richard A. Kozarek, Stanford E. Sumida, P. Pethigal
Publikováno v:
Gastrointestinal endoscopy. 43(5)
Background: High-level disinfection of endoscopes has traditionally been undertaken by manual or automatic scope cleaning plus a 10 to 20 minute soak in 2% alkaline glutaraldehyde. Mycobacteria species are less sensitive to glutaraldehyde, and a 45-m
Publikováno v:
Gastrointestinal endoscopy. 43(1)
Background: Disposable biopsy forceps have been heavily marketed as cost-effective, convenient, and safer to use than conventional forceps. Methods: In an attempt to define whether disposable or reusable biopsy forceps were cheaper to use, we prospec
Publikováno v:
Gastrointestinal Endoscopy. 51:AB66
Background: It has been suggested that single-use biopsy forceps will prevent inter-patient transmission of infection during endoscopy. Passage of sterile forceps through the biopsy channel can lead to contamination, however, if the endoscope is inad
Autor:
Martin D. Gelfand, Richard A. Kozarek, S K Roach, Michael Gluck, Stanford E. Sumida, Geoffrey C. Jiranek, Shirley L. Raltz, James E. Bredfeldt, John J. Brandabur, Fouad M. Attia, David J. Patterson, Drew B. Schembre
Publikováno v:
Gastrointestinal Endoscopy. 51:AB86
Disposable biopsy (bx) forceps are marketed as more efficacious and safer than reusable ones, but there are few data to support these claims. We report the continuation of a prospective study begun in1998 to evaluate invivo efficacy of a reusable bx
Autor:
Shirley L. Raltz, Richard A. Kozarek, David C. Irizarry, Stanford E. Sumida, Linda D. Merriam
Publikováno v:
Gastrointestinal Endoscopy. 43:316
Autor:
Richard A. Kozarek, Linda D. Merriam, Shiro Urayama, Stanford E. Sumida, P. Pethigal, Shirley L. Raltz
Publikováno v:
Gastrointestinal Endoscopy. 41:331