Mantel, C., Spataru, S.V., Del Prado Santamaría, R., Poulsen, P.B., Dos Reis Benatto, G.A., Forchhammer, S.
8th World Conference on Photovoltaic Energy Conversion; 448-453
This paper presents a method to increase the dynamic range of the EL signal for diagnostics of defective areas in PV modules. It applies a computational method for reconstructing a
This paper presents a method to increase the dynamic range of the EL signal for diagnostics of defective areas in PV modules. It applies a computational method for reconstructing a
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9e85af93c4735ce513a0bd563f4a014c
8th World Conference on Photovoltaic Energy Conversion; 642-645
Satinated glass is an increasingly important component of PV modules, especially in the building integrated (BIPV) sector, where it can contribute to more uniform appearance as well
Satinated glass is an increasingly important component of PV modules, especially in the building integrated (BIPV) sector, where it can contribute to more uniform appearance as well
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::834661d17edab37d553595be22b37f0c
Autor:
Del Prado Santamaría, R., Hass, T.K., Dos Reis Benatto, G.A., Ng, J.W., Poulsen, P.B., Spataru, S.V.
8th World Conference on Photovoltaic Energy Conversion; 480-487
In this work, we present and validate a machine learning approach for estimating power loss in monocrystalline silicon PV cells due to cell cracks. The primary focus is selection an
In this work, we present and validate a machine learning approach for estimating power loss in monocrystalline silicon PV cells due to cell cracks. The primary focus is selection an
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5ff772a009cc1c20277d497f710ffba9
Autor:
Dos Reis Benatto, G.A., Del Prado Santamaría, R., Hass, T.K., Bartholomäus, M., Morino, L., Poulsen, P.B., Spataru, S.V.
8th World Conference on Photovoltaic Energy Conversion; 735-739
With the growth of photovoltaic plant installations in quantity and size, the operations & maintenance industry calls for more efficient and accurate ways to inspect the PV modules
With the growth of photovoltaic plant installations in quantity and size, the operations & maintenance industry calls for more efficient and accurate ways to inspect the PV modules
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0d716be5c80bed1e0d67b29474365a9f
Autor:
Hass, T.K., Spataru, S.V., Santamaria Lancia, A.A., Parikh, H.R., Poulsen, P.B., Dos Reis Benatto, G.A.
37th European Photovoltaic Solar Energy Conference and Exhibition; 1573-1579
Electroluminescence (EL) imaging is a powerful technique for evaluating the condition of photovoltaic (PV) modules and individual cells. While drones are a cheap and pr
Electroluminescence (EL) imaging is a powerful technique for evaluating the condition of photovoltaic (PV) modules and individual cells. While drones are a cheap and pr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ca118c930de69ba72cff6fb42db5261a
37th European Photovoltaic Solar Energy Conference and Exhibition; 1053-1057
Electroluminescence imaging is a very powerful technique for PV fault diagnosis, although having to contact electrically the panels during measurement is a complex and
Electroluminescence imaging is a very powerful technique for PV fault diagnosis, although having to contact electrically the panels during measurement is a complex and
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::362fec60d66e5fda6258352719e11d5c
Autor:
Spataru, S.V., Dos Reis Benatto, G.A., Hass, T.K., Santamaria Lancia, A.A., Poulsen, P.B., Thorsteinsson, S.
37th European Photovoltaic Solar Energy Conference and Exhibition; 1130-1135
The severity of solar cell cracks is most often evaluated qualitatively, by assigning them to one of several categories. In this work we propose a machine analysis frie
The severity of solar cell cracks is most often evaluated qualitatively, by assigning them to one of several categories. In this work we propose a machine analysis frie
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::779ac6b98059c1c569c18b2a6e346c1e
36th European Photovoltaic Solar Energy Conference and Exhibition; 986-990
Partial shading affects the performance and reliability of thin-film and crystalline-silicon (c-Si) photovoltaic (PV) modules. In this paper, the thin-film and c-Si modul
Partial shading affects the performance and reliability of thin-film and crystalline-silicon (c-Si) photovoltaic (PV) modules. In this paper, the thin-film and c-Si modul
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::8ae75f1c1b2ba040102f34c9f403bc5a
Autor:
Spataru, S.V., Sera, D., Parikh, H.R., Dos Reis Benatto, G.A., Mantel, C., Poulsen, P.B., Forchhammer, S.
36th European Photovoltaic Solar Energy Conference and Exhibition; 860-865
Electroluminescence (EL) imaging of photovoltaic (PV) modules requires careful selection of the measurement parameters, such as camera sensor exposure time, for obtaining
Electroluminescence (EL) imaging of photovoltaic (PV) modules requires careful selection of the measurement parameters, such as camera sensor exposure time, for obtaining
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::122fe27365c3d182663dfae359ba53c7
Autor:
Dos Reis Benatto, G.A., Mantel, C., Santamaria Lancia, A.A., Villebro, F., Riedel, N., Thorsteinsson, S., Poulsen, P.B., Forchhammer, S., Parikh, H.R., Spataru, S.V., Sera, D.
36th European Photovoltaic Solar Energy Conference and Exhibition; 1651-1655
In this paper, we present a study of daylight EL acquisition and the results of a sunlight variation study in a scenario necessary to assure the increase of EL image qu
In this paper, we present a study of daylight EL acquisition and the results of a sunlight variation study in a scenario necessary to assure the increase of EL image qu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2ab625967ea69f7a71636a38333c9c08