Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Silvan Mueller"'
Autor:
Hannes A. Loebner, Jenny Bertholet, Paul-Henry Mackeprang, Werner Volken, Olgun Elicin, Silvan Mueller, Gian Guyer, Daniel M. Aebersold, Marco F.M. Stampanoni, Michael K. Fix, Peter Manser
Publikováno v:
Physics and Imaging in Radiation Oncology, Vol 30, Iss , Pp 100586- (2024)
Background and purpose: Dynamic trajectory radiotherapy (DTRT) has been shown to improve healthy tissue sparing compared to volumetric arc therapy (VMAT). This study aimed to assess and compare the robustness of DTRT and VMAT treatment-plans for head
Externí odkaz:
https://doaj.org/article/f3e6d6ed01824165843d972a9c5d3cea
Autor:
Jenny Bertholet, Paul-Henry Mackeprang, Silvan Mueller, Gian Guyer, Hannes A. Loebner, Yanick Wyss, Daniel Frei, Werner Volken, Olgun Elicin, Daniel M. Aebersold, Michael K. Fix, Peter Manser
Publikováno v:
Radiation Oncology, Vol 17, Iss 1, Pp 1-11 (2022)
Abstract Background Dynamic trajectory radiotherapy (DTRT) extends volumetric modulated arc therapy (VMAT) with dynamic table and collimator rotation during beam-on. The aim of the study is to establish DTRT path-finding strategies, demonstrate deliv
Externí odkaz:
https://doaj.org/article/608ac9a5d1b64eed8e043e44e9ddf852
Autor:
Hannes A. Loebner, Werner Volken, Silvan Mueller, Jenny Bertholet, Paul‐Henry Mackeprang, Gian Guyer, Daniel M. Aebersold, Marco F. M. Stampanoni, Peter Manser, Michael K. Fix
Publikováno v:
Loebner, H A; Volken, W; Mueller, S; Bertholet, J; Mackeprang, P-H; Guyer, G; Aebersold, D M; Stampanoni, Mfm; Manser, P; Fix, M K (2022). Development of a Monte Carlo based robustness calculation and evaluation tool. Medical physics, 49(7), pp. 4780-4793. American Association of Physicists in Medicine AAPM 10.1002/mp.15683
Medical Physics, 49 (7)
Medical Physics, 49 (7)
Background: Evaluating plan robustness is a key step in radiotherapy. Purpose: To develop a flexible Monte Carlo (MC)-based robustness calculation and evaluation tool to assess and quantify dosimetric robustness of intensity-modulated radiotherapy (I
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::88e44e4c8f419fa901311e437daf4aab
Autor:
Peter Manser, Michael K. Fix, Daniel M. Aebersold, Olgun Elicin, G. Guyer, Alisha Duetschler, Silvan Mueller, Emily Heath
Publikováno v:
Heath, Emily; Mueller, Silvan; Guyer, Gian; Duetschler, Alisha; Eliçin, Olgun; Aebersold, Daniel; Fix, Michael K.; Manser, Peter (2021). Implementation and experimental validation of a robust hybrid direct aperture optimization approach for mixed-beam radiotherapy. Medical physics, 48(11), pp. 7299-7312. Wiley 10.1002/mp.15258
Medical Physics, 48 (11)
Medical Physics, 48 (11)
Purpose The objectives of the work presented in this paper were to (1) implement a robust-optimization method for deliverable mixed-beam radiotherapy (MBRT) plans within a previously developed MBRT planning framework; (2) perform an experimental vali
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8cc9ae5dde6c84cc5835f4d1c1f59ad2
https://boris.unibe.ch/160329/1/mp.15258.pdf
https://boris.unibe.ch/160329/1/mp.15258.pdf
Autor:
Peter Manser, Daniel Frei, R. Kueng, Daniel M. Aebersold, Marco Stampanoni, Silvan Mueller, Werner Volken, Michael K. Fix, Hannes Anton Loebner
Publikováno v:
Küng, Reto; Mueller, Silvan; Löbner, Hannes Anton; Frei, Daniel; Volken, Werner; Aebersold, Daniel M.; Stampanoni, Marco F M; Fix, Michael K.; Manser, Peter (2021). TriB-RT: simultaneous optimization of photon, electron and proton beams. Physics in medicine and biology, 66(4), 045006. Institute of Physics Publishing IOP 10.1088/1361-6560/ab936f
Purpose. To develop a novel treatment planning process (TPP) with simultaneous optimization of modulated photon, electron and proton beams for improved treatment plan quality in radiotherapy. Methods. A framework for fluence map optimization of Monte
Autor:
Werner Volken, Olgun Elicin, Daniel Frei, Daniel M. Aebersold, Hossein Hemmatazad, D. Terribilini, Peter Manser, Silvan Mueller, Michael K. Fix
Publikováno v:
Medical Physics. 45:4201-4212
PURPOSE Although volumetric modulated arc therapy (VMAT) is a well-accepted treatment technique in radiotherapy using a coplanar delivery approach, VMAT might be further improved by including dynamic table and collimator rotations leading to dynamic
Autor:
D. Henzen, Michael K. Fix, Silvan Mueller, Marco Stampanoni, R. Kueng, Werner Volken, Daniel Frei, A. Joosten, Daniel M. Aebersold, Peter Manser
Publikováno v:
Physics in Medicine & Biology. 62:5840-5860
The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct ape
Publikováno v:
Intelligent Autonomous Systems 15 ISBN: 9783030013691
IAS
IAS
This paper contributes to a mechanical/kinematical design of a stair climbing robot. Based on the known Klann-mechanism, an extended re-configurable mechanism is proposed, in order to address the stair climbing problem. Steps offer a great variety of
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ec0bdd521948e48123d0808c6b5b26d3
https://doi.org/10.1007/978-3-030-01370-7_22
https://doi.org/10.1007/978-3-030-01370-7_22
Autor:
Marco Stampanoni, Werner Volken, M. Malthaner, Diem Vuong, Paul-Henry Mackeprang, Daniel Frei, Daniel M. Aebersold, A. Dal Pra, Daniel Schmidhalter, Michael K. Fix, D. Henzen, Silvan Mueller, Peter Manser
Publikováno v:
Physics in medicine and biology. 63(1)
This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA