Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Shuji Qin"'
Autor:
Shuji Qin, Weixing Tang, Xiangdong Xu, Lingyan Chen, Yonggang Wu, Jie Zhu, Shaojun Fu, Zhanshan Wang, Yilin Hong, Mingqi Cui
Publikováno v:
Chinese Science Bulletin. 48:1930-1933
The soft X-ray interferometry is completed by the Mach-Zehnder interferometer using a soft X-ray laser, and it is also an important method to measure the electron densities of a laser-produced plasma near the critical surface. It is apparently demons
Publikováno v:
Sensors and Actuators B: Chemical. 66:240-242
The sensitivity to SO 2 of the SAW gas sensor coated with triethanolamine (TEA) modified with boric acid (H 3 BO 3 ) (TEA and H 3 BO 3 were mixed with a mole ratio 3:1) has been investigated. A better stability of the modified TEA film compared with
Publikováno v:
Springer Proceedings in Physics ISBN: 9781402060175
In EUV and X-ray regions, multilayer mirrors are the essential and necessary optics elements. The good prospects of the EUV and X-ray optics for next generation lithography system, microscopy in the “water windows”, astronomy telescope, spectrosc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d7e94d04340bba8da3bbccfb0b53d34f
https://doi.org/10.1007/978-1-4020-6018-2_50
https://doi.org/10.1007/978-1-4020-6018-2_50
Publikováno v:
Springer Proceedings in Physics ISBN: 9781402060175
A grazing Kirkpatrick-Baez (K-B) microscope was designed for hard x-ray (8keV; Cu Ka radiation) imaging in Inertial Confinement Fusion (ICF) diagnostic experiments. Ray tracing software was used to simulate optical system performance. The optimized t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e8cb853424bb63351d2b0f4293b69235
https://doi.org/10.1007/978-1-4020-6018-2_71
https://doi.org/10.1007/978-1-4020-6018-2_71
Autor:
Zhanshan Wang, Bei Wang, Wenjuan Wu, Fengli Wang, Shumin Zhang, Shuji Qin, Zhong Zhang, Zhongxiang Gu, Lingyan Chen, Xinbin Cheng, Hongchang Wang
Publikováno v:
SPIE Proceedings.
The present status of studies on EUV, soft x-ray and x-ray multilayer in the Institute of Precision Optical Engineering (IPOE) is briefly reviewed. With the aim of realizing a Mach-Zender interferometer working at 13.9nm, we have developed a semitran
Autor:
Hongchang Wang, Shuji Qin, Zhanshan Wang, Zhongxiang Gu, Shumin Zhang, Wenjuan Wu, Yao Xu, Lingyan Chen, Fengli Wang, Zhong Zhang
Publikováno v:
SPIE Proceedings.
The periodic mulitlayer with high reflectivity and small full width at half maximum (FWHM) in hard x-ray range, while the reflectivity of non-periodic multilayer decreases and FWHM increase. Therefore, the optimum coating design must be found out as
Autor:
Zhanshan Wang, Lingyan Chen, Zhong Zhang, Wennjuan Wu, Shuji Qin, Hongchang Wang, Fengli Wang
Publikováno v:
SPIE Proceedings.
We designed two kinds of supermirrors composed of Carbon and Tungsten in current paper. Using Simplex Optimization method, we designed C/W supermirror with broad incident angular range (0.5°~0.9°) at Cu Kα line (λ=0.154nm). Connecting the analyti
Autor:
Shuji Qin, Shumin Zhang, Xinbin Chen, Hongchang Wang, Zhong Zhang, Lingyan Chen, Bei Wang, Zhanshan Wang, Fengli Wang, Yao Xu, Wenjuan Wu
Publikováno v:
SPIE Proceedings.
The broadband x-ray supermirrors have been designed, fabricated and studied experimentally. They are intended for operating in the photon energy range from 12.4 to 20keV at the fixed grazing incident angle of 0.5°. The choice of material pairs compo
Autor:
Bei Wang, Shumin Zhang, Zhong Zhang, Wenjuan Wu, Shuji Qin, Zhanshan Wang, Lingyan Chen, Yao Xu, Zhongxiang Gu, Fengli Wang, Xinbin Cheng, Hongchang Wang
Publikováno v:
SPIE Proceedings.
The status of polarizing optical elements for the soft x-ray range is reviewed. The criteria for optimum polarization of soft x-ray reflective analyzers, transmission polarizers and phase retarders based on multilayer interference structures are pres
Publikováno v:
SPIE Proceedings.
K-B microscope intended for the use in inertial confinement fusion experiments was designed. The microscope operates at the 8keV x-ray energy and provides the 8X magnification. The parameters of the microscope are decided by requirements of ICF exper