Bozhi Cheng, Yaoxian Yang, Shuhang Shen, Zhongdong Wang, Peter Crossley, Gordon Wilson, Andrew Fieldsend‐Roxborough
Publikováno v:
IET Electric Power Applications, Vol 18, Iss 3, Pp 265-277 (2024)
Abstract The lumped element network model has been proven to be an efficient tool for the interpretation of transformer Frequency Response Analysis. However, it is challenging to obtain parameters of the model if transformer design information is una
Externí odkaz:
https://doaj.org/article/cfbac06d3bcb4abda6b71daf2d187bf0
Publikováno v:
IET Generation, Transmission & Distribution, Vol 16, Iss 23, Pp 4663-4671 (2022)
Abstract The UK net‐zero target requires the integration of significant renewable energy resources into the electrical grid. This, together with the projected growth in electricity demand imposes practical challenges on the power transfer capabilit
Externí odkaz:
https://doaj.org/article/ac8784abbd604fc28ad2797692b794c2
Publikováno v:
IEEE Sensors Journal. 22:21172-21178
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 71:1-8
Publikováno v:
2022 9th International Conference on Condition Monitoring and Diagnosis (CMD).
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 28:1136-1144
The electric field uniformity imposes a significant effect on the breakdown mechanisms of dielectric liquids. In general, breakdown is dominated by streamer initiation under uniform field, while it is dominated by streamer propagation under non-unifo
Publikováno v:
Circuits, Systems, and Signal Processing. 40:5825-5846
This paper proposes three modified memristor ratioed logic (MRL) gates: NOT, NOR and A AND (NOR B) (i.e., $$A \cdot \bar{B}$$ ), each of which only needs 1 memristor and 1 NMOS. Based on the modified MRL gates, we design some combinational logic circ
Publikováno v:
IEEE Transactions on Plasma Science. 49:1962-1968
Under rain conditions, the sliding water droplets on the insulator’s surface shorten the air insulation distance between the sheds and even cause a flashover. In order to study the mechanism of air gap breakdown with rain droplets, the breakdown pr
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 28:493-501
This paper presents an experimental study focusing on the quantitative analyses of spatial characteristics of Mach-cone shaped shockwaves generated by streamers in a mineral oil and a synthetic ester in a fixed 12 mm needle-plane gap under positive l
Publikováno v:
IET Generation, Transmission & Distribution. 14:3332-3337
In this study, to improve the sensitivity and accuracy of the detection of surface partial discharge (PD) in gas insulation switchgears (GISs), a combination of ultra-high frequency (UHF) and optical methods is proposed based on an integrated sensor.