Zobrazeno 1 - 10
of 26
pro vyhledávání: '"Shu, Yamashita"'
Autor:
Akira Mizukami, Shota Miyakuni, Ryo Nakada, Tetsuya Kobayashi, Takuya Kawakami, Koki Takegawa, Hirofumi Arai, Jiro Hiroki, Kenji Yoshioka, Hirofumi Otani, Maki Ono, Shu Yamashita, Daisuke Ueshima, Makoto Suzuki, Akihiko Matsumura, Masahiko Goya, Tetsuo Sasano
Publikováno v:
Journal of Arrhythmia, Vol 39, Iss 1, Pp 10-17 (2023)
Abstract Background Micra leadless pacemaker is secured to the myocardium by engagement of at least 2/4 tines confirmed with pull and hold test. However, the pull and hold test is sometimes difficult to assess. This study was performed to evaluate wh
Externí odkaz:
https://doaj.org/article/8e5a7f4d8a0048c99e9dc16d9c70cba9
Autor:
Kenichiro Takeda, Akira Naito, Toshihiko Sugiura, Masaki Ishige, Kohei Shikano, Mitsuhiro Abe, Hajime Kasai, Shota Miyakuni, Shu Yamashita, Ayako Shigeta, Seiichiro Sakao, Takuji Suzuki
Publikováno v:
Internal Medicine. 62:275-279
Autor:
Akira Mizukami, Shota Miyakuni, Ryo Nakada, Tetsuya Kobayashi, Takuya Kawakami, Koki Takegawa, Hirofumi Arai, Jiro Hiroki, Kenji Yoshioka, Hirofumi Otani, Maki Ono, Shu Yamashita, Daisuke Ueshima, Makoto Suzuki, Akihiko Matsumura, Masahiko Goya, Tetsuo Sasano
Publikováno v:
Journal of Arrhythmia. 39:10-17
Autor:
Kazuto Hayasaka, Takeshi Sasaki, Yasuhiro Shirai, Hikaru Shimosato, Tomohiro Tahara, Shota Segami, Ryo Nagasawa, Ko Akimoto, Kento Yabe, Chisashi Toya, Keita Watanabe, Shu Yamashita, Masahito Suzuki, Koji Sugiyama, Yasuteru Yamauchi, Kaoru Okishige, Masahiko Goya, Tetsuo Sasano
Publikováno v:
Pacing and Clinical Electrophysiology.
Autor:
Hirofumi Arai, Akira Mizukami, Yoshihiro Hanyu, Takuya Kawakami, Yuki Shimizu, Jiro Hiroki, Kenji Yoshioka, Hirofumi Ohtani, Maki Ono, Shu Yamashita, Ryota Iwatsuka, Daisuke Ueshima, Akihiko Matsumura, Masahiko Goya, Tetsuo Sasano
Publikováno v:
Pacing and Clinical Electrophysiology. 45:196-203
Implantations of leadless pacemakers in the septum lower the risk of cardiac perforation. However, the relationship between the implantation site and the success rate, complication rate, and pacemaker parameters are not well-investigated.Patients who
Autor:
Tatsuhiko Hirao, Yasuteru Yamauchi, Hironori Sato, Shu Yamashita, Atsuhiko Yagishita, Takamichi Miyamoto, Masahiko Goya, Kenzo Hirao
Publikováno v:
Indian Pacing and Electrophysiology Journal, Vol 17, Iss 5, Pp 150-152 (2017)
We present a case of a 37-year-old female who complained of frequent palpitations caused by an atrial tachycardia and atrial premature contractions. Angiography revealed that the coronary sinus was occluded at the ostium and connected to a persistent
Externí odkaz:
https://doaj.org/article/9d77c4065c42464fa4782954bb310b9f
Autor:
Koji Sugiyama, Kento Yabe, Takeshi Sasaki, Masahiko Goya, Shu Yamashita, Ko Akimoto, Chisashi Toya, Tetsuo Sasano, Kazuto Hayasaka, Masahito Suzuki
Publikováno v:
Pacing and Clinical Electrophysiology. 44:1331-1339
BACKGROUND Subselection inner catheters (Inner-Cath) are used adjunctively with outer guiding catheters (Outer-Cath) during cardiac resynchronization therapy (CRT) device implantation. This study aims to investigate the feasibility and efficacy of le
Autor:
Kenichiro, Takeda, Akira, Naito, Toshihiko, Sugiura, Masaki, Ishige, Kohei, Shikano, Mitsuhiro, Abe, Hajime, Kasai, Shota, Miyakuni, Shu, Yamashita, Ayako, Shigeta, Seiichiro, Sakao, Takuji, Suzuki
Publikováno v:
Internal medicine (Tokyo, Japan).
We herein report a case of pulmonary veno-occlusive disease (PVOD) induced by allo-hematopoietic stem cell transplantation (HSCT) in a 48-year-old man who was diagnosed with acute myeloid leukemia. Five months after transplantation, he developed dysp
Publikováno v:
HeartRhythm Case Reports
Autor:
Masakazu Kaneko, Kenzo Hirao, Tasuku Yamamoto, Mihoko Kawabata, Takeshi Sasaki, Masahito Suzuki, Masahiko Goya, Atsuhiko Yagishita, Yasuhiro Shirai, Shu Yamashita, Masahiro Sekigawa, Kikou Akiyoshi, Yoshihide Takahashi, Shingo Maeda
Publikováno v:
Journal of Interventional Cardiac Electrophysiology. 56:249-257
Ripple map (RM) is a novel method for displaying activation pattern on the surface of a cardiac chamber. The aim of this study was to determine the utility of the RM in interpreting the atrial propagation in atrial tachycardia (AT) in comparison with