Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Shreyas B. Raghunathan"'
Autor:
Hendrik J. Vos, Sandra Blaak, Nico de Jong, Zhao Chen, Johan G. Bosch, Michiel A. P. Pertijs, Chao Chen, Maysam Shabanimotlagh, Emile Noothout, Zu-yao Chang, Jacco Ponte, Shreyas B. Raghunathan, Martin D. Verweij, Zili Yu, Christian Prins
Publikováno v:
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 63(1), 47-59. Institute of Electrical and Electronics Engineers Inc.
This paper presents the design, fabrication, and experimental evaluation of a prototype lead zirconium titanate (PZT) matrix transducer with an integrated receive ASIC, as a proof of concept for a miniature three-dimensional (3-D) transesophageal ech
Publikováno v:
Dreissen, L S, Schouten, H F, Ubachs, W, Raghunathan, S B & Visser, T D 2018, ' Active Two-Dimensional Steering of Radiation from a Nanoaperture ', Nano Letters, vol. 18, no. 11, pp. 7207-7210 . https://doi.org/10.1021/acs.nanolett.8b03319
Nano Letters
Nano Letters, 18(11), 7207-7210. American Chemical Society
Nano Letters
Nano Letters, 18(11), 7207-7210. American Chemical Society
We experimentally demonstrate control over the direction of radiation of a beam that passes through a square nano-aperture in a metal film. The ratio of the aperture size and the wavelength is such that only three guided modes, each with different sp
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e755ba760ccd5bbe3647b65bb04b829f
https://hdl.handle.net/1871.1/6d798748-db69-4bfd-ac56-555d2e3f362d
https://hdl.handle.net/1871.1/6d798748-db69-4bfd-ac56-555d2e3f362d
Autor:
Zhao Chen, Hendrik J. Vos, Verya Daeichin, Nico de Jong, Maysam Shabani Motlagh, Emile Noothout, Shreyas B. Raghunathan, Johan G. Bosch, Deep Bera, Martin D. Verweij, Chao Chen, Michiel A. P. Pertijs
Publikováno v:
Ultrasound in Medicine & Biology, 44(10)
Ultrasound in Medicine and Biology, 44(10), 2143-2154. Elsevier Inc.
Ultrasound in Medicine and Biology, 44(10), 2143-2154. Elsevier Inc.
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT ele
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::cbd48424e89fd35c12795617b316709f
http://resolver.tudelft.nl/uuid:d9668c81-01da-4ae6-beaa-a910f8d1037c
http://resolver.tudelft.nl/uuid:d9668c81-01da-4ae6-beaa-a910f8d1037c
Autor:
Shreyas B. Raghunathan, Zhao Chen, Hendrik J. Vos, Chao Chen, Deep Bera, Verya Daeichin, Johannes G. Bosch, Michiel A. P. Pertijs, A.F.W. van der Steen, Martin D. Verweij, N. de Jong
Publikováno v:
Physics in Medicine and Biology, 63(7):075015. IOP Publishing Ltd.
Physics in Medicine and Biology, 63(7)
Physics in Medicine and Biology, 63(7)
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound syste
Autor:
Pieter Kruizinga, Verya Daeichin, Hendrik J. Vos, Michiel A. P. Pertijs, Maysam Shabanimotlagh, Shreyas B. Raghunathan, Johannes G. Bosch, Nico de Jong, Martin D. Verweij
Publikováno v:
2017 IEEE International Ultrasonics Symposium (IUS).
Over the last decade, clinical studies show a strong interest for real-time 3D imaging. This calls for ultrasound probes with high-element-count 2D matrix transducer array, interfaced to an imaging system using an in-probe Application Specific Integr
Autor:
Verya Daeichin, Hendrik J. Vos, Martin D. Verweij, Michiel A. P. Pertijs, Johannes G. Bosch, Shreyas B. Raghunathan, Maysam Shabanimotlagh, Nico de Jong, Pieter Kruizinga
Publikováno v:
2017 IEEE International Ultrasonics Symposium (IUS).
Over the last decade, clinical studies show a strong interest in real-time 3D imaging. This calls for ultrasound probes with high-element-count 2D matrix transducer arrays. These may be interfaced to an imaging system using an in-probe Application Sp
Autor:
Shreyas B. Raghunathan, Hendrik J. Vos, Maysam Shabanimotlagh, Deep Bera, Christian Prins, Zhao Chen, Emile Noothout, Martin D. Verweij, Michiel A. P. Pertijs, Zu-yao Chang, Chao Chen, Jacco Ponte, Johan G. Bosch, Nico de Jong
Publikováno v:
IEEE Journal of Solid State Circuits, 52(4)
IEEE Journal of Solid-State Circuits, 52(4), 994-1006. Institute of Electrical and Electronics Engineers Inc.
IEEE Journal of Solid-State Circuits, 52(4), 994-1006. Institute of Electrical and Electronics Engineers Inc.
This paper presents a power- and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of $32 \times 32$ piezoelectric transducer elements to enable next-generation miniature ultrasound prob
Autor:
Michiel A. P. Pertijs, Nico de Jong, Jovana Janjic, Martin D. Verweij, Maysam Shabanimotlagh, Shreyas B. Raghunathan
Publikováno v:
2016 IEEE International Ultrasonics Symposium (IUS).
Accurate diagnostics of stenosis and blood flow distribution in carotid arteries requires transducers capable of producing 3D volume images with high frame rate for real time imaging. In the process of designing a matrix probe, an important goal is t
Autor:
Hendrik J. Vos, Deep Bera, Martin D. Verweij, Shreyas B. Raghunathan, Chao Chen, N. de Jong, Michiel A. P. Pertijs, Zhao Chen, Johannes G. Bosch
Publikováno v:
2016 IEEE International Ultrasonics Symposium (IUS).
A general challenge in 3D volumetric imaging is the large channel count. One solution uses integrated microbeamformers. The reconstruction of the entire volume from these micro-beamformed datasets can be performed in many ways. In this paper we propo
Autor:
Emile Noothout, Deep Bera, Zhao Chen, Christian Prins, Hendrik J. Vos, Johannes G. Bosch, Zu-yao Chang, Martin D. Verweij, Shreyas B. Raghunathan, Maysam Shabanimotlagh, Jacco Ponte, N. de Jong, Chao Chen, Michiel A. P. Pertijs
Publikováno v:
VLSI Circuits
This paper presents a power- and area-efficient front-end ASIC that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable the next-generation miniature ultrasound probes for real-time 3-D transesophageal echocar