Publikováno v:
Applied Sciences, Vol 12, Iss 11, p 5659 (2022)
In computed tomography imaging, the computationally intensive tasks are the pre-processing of 2D detector data to generate total attenuation or line integral projections and the reconstruction of the 3D volume from the projections. This paper propose
Externí odkaz:
https://doaj.org/article/82d28d7db2c2406e9f40a94f36e03d97
Publikováno v:
IEEE Transactions on Radiation and Plasma Medical Sciences. 7:354-371
Publikováno v:
15th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine.
Metal artifacts are increasingly prevalent in CT reconstructed volumes due to the presence of implants in the aging population. High degree of beam hardening in severely attenuating objects is one of the main contributors of strong metal artifacts. I
Publikováno v:
15th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine.
Due to wide cone angle, the artifacts caused by scatter radiation are inevitable in flat detector CT reconstructed images. Cupping and streak artifacts are the main manifestations of scatter artifacts which will degrade low contrast resolution and Ho
Publikováno v:
15th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine.
The polychromatic X-ray spectrum and the energy-dependent material attenuation coefficients generate beam hardening artifacts in CT reconstructed images. The artifacts can be corrected by projection linearization using polynomials. Recently, consiste
Autor:
Richard N K, Bismark, Robert, Frysch, Shiras, Abdurahman, Oliver, Beuing, Manuel, Blessing, Georg, Rose
Publikováno v:
Zeitschrift fur medizinische Physik. 30(1)
This work aims at the compensation of beam hardening artifacts by the means of an extended three-dimensional polychromatic statistical reconstruction to be applied for flat panel cone-beam CT.We implemented this reconstruction technique as being intr
Publikováno v:
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).
The polychromatic X-ray spectrum and the energy-dependent attenuation coefficients of the imaged object introduce beam hardening artifacts in CT reconstructed volumes. Cupping, streak, and spill-over are the different manifestations of beam hardening
Publikováno v:
IEEE transactions on medical imaging. 37(10)
The polychromatic X-ray spectrum and the energy-dependent attenuation coefficient of materials cause beam hardening artifacts in CT reconstructed volumes. These artifacts appear as cupping and streak artifacts depending on the material composition an
Publikováno v:
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD).
Due to polychromatic nature of the X-ray spectrum, beam hardening artifacts are introduced in cone beam computed tomography reconstructed images. To reduce these artifacts, projection images can be linearized with higher order polynomials. Polynomial
Publikováno v:
Breast Imaging ISBN: 9783319078861
Digital Mammography / IWDM
Digital Mammography / IWDM
In Digital Breast Tomosynthesis, a 3D representation of the breast is reconstructed from low-dose projection images acquired over a limited angular range. Each such image contains high level of noise which is often counteracted by a projection binnin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a863d48cf750370533f3e1e9b1575ccd
https://doi.org/10.1007/978-3-319-07887-8_73
https://doi.org/10.1007/978-3-319-07887-8_73