Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Shih-Liang Chiu"'
Publikováno v:
Sensors, Vol 14, Iss 8, Pp 13815-13829 (2014)
This paper presents a novel class of miniature fluxgate magnetometers fabricated on a print circuit board (PCB) substrate and electrically connected to each other similar to the current “flip chip” concept in semiconductor package. This sensor is
Externí odkaz:
https://doaj.org/article/47c32e5513024b55b50f529d2d1707b4
Autor:
Shih-Liang Chiu, 邱士良
102
In this study, we design and fabricate a micro fluxgate magnetic sensor with dual magnetic cores by CMOS process and BGA (Ball Grid Array) flip-chip techniques, and analyze the effect caused by different design. The micro fluxgate fabricated
In this study, we design and fabricate a micro fluxgate magnetic sensor with dual magnetic cores by CMOS process and BGA (Ball Grid Array) flip-chip techniques, and analyze the effect caused by different design. The micro fluxgate fabricated
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/m59k26
Publikováno v:
Sensors (Basel, Switzerland)
Sensors, Vol 14, Iss 8, Pp 13815-13829 (2014)
Sensors; Volume 14; Issue 8; Pages: 13815-13829
Sensors, Vol 14, Iss 8, Pp 13815-13829 (2014)
Sensors; Volume 14; Issue 8; Pages: 13815-13829
This paper presents a novel class of miniature fluxgate magnetometers fabricated on a print circuit board (PCB) substrate and electrically connected to each other similar to the current "flip chip" concept in semiconductor package. This sensor is sol
Publikováno v:
Modelling and Simulation / 804: Signal and Image Processing.
Autor:
Shih-Liang Chiu, Paul S. Ho
Publikováno v:
MRS Proceedings. 203
The fracture behavior of the Au(Cr)/PMDA-ODA interface was investigated using a stretch deformation method. The study has been focused on thc effects of metal dimension on the delamination behavior, the fracture morphology, and energy dissipation rat
Autor:
Shih‐Liang Chiu, R. E. Acosta
Publikováno v:
Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures. 8:1589
In order to maintain the dimensional accuracy of an x‐ray mask, the residual stress of the absorber must be kept low (in the low range of 108 dyn/cm2 ). The absorber material studied in this paper is pure gold electroplated from a proprietary plati
Publikováno v:
MRS Proceedings. 167
The fracture behavior of metal-polymer line structures as a function of dimensions was investigated using a stretch-deformation technique. The effects of line orientation, line width and film thickness are reported in this paper. When the line orient
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.