Zobrazeno 1 - 10
of 16
pro vyhledávání: '"Shih-Chun Jin"'
Publikováno v:
Sensors, Vol 24, Iss 6, p 1947 (2024)
Graphics processing units (GPUs) facilitate massive parallelism and high-capacity storage, and thus are suitable for the iterative reconstruction of ultrahigh-resolution micro computed tomography (CT) scans by on-the-fly system matrix (OTFSM) calcula
Externí odkaz:
https://doaj.org/article/21d02394a5a74a299841d3e98d43c27a
Publikováno v:
PLoS ONE, Vol 14, Iss 1, p e0209674 (2019)
To further reduce the noise and artifacts in the reconstructed image of sparse-view CT, we have modified the traditional total variation (TV) methods, which only calculate the gradient variations in x and y directions, and have proposed 8- and 26-dir
Externí odkaz:
https://doaj.org/article/146c29ca752d48da9405923a554fb689
Autor:
Shih-Chun Jin, Chia-Jui Hsieh, Jyh-Cheng Chen, Shih-Huan Tu, Ya-Chen Chen, Tzu-Chien Hsiao, Angela Liu, Wen-Hsiang Chou, Woei-Chyn Chu, Chih-Wei Kuo
Publikováno v:
Sensors, Vol 18, Iss 12, p 4458 (2018)
Limited-angle iterative reconstruction (LAIR) reduces the radiation dose required for computed tomography (CT) imaging by decreasing the range of the projection angle. We developed an image-quality-based stopping-criteria method with a flexible and i
Externí odkaz:
https://doaj.org/article/c430df60e73f42278062b49f543be3d2
Publikováno v:
Journal of Medical and Biological Engineering. 39:901-911
As the X-ray imaging market keeps expanding and digital X-ray detector technology has become more important, the International Electro Technical Commission has developed an IEC 62220-1 standard for the device to cope with medical imaging report requi
Purpose: Cone-beam computed tomography (CBCT) has been widely applied in dental and maxillofacial imaging. Several dental CBCT systems have been recently developed in order to improve the performance. This study aimed to evaluate the image quality of
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a1f1dae59dd7188a907ef16b8228522b
https://doi.org/10.21203/rs.3.rs-165836/v1
https://doi.org/10.21203/rs.3.rs-165836/v1
Publikováno v:
Journal of computer assisted tomography. 45(1)
The purpose of this study was to evaluate the relationship between radiation dose and noise level on various coronary calcium scoring protocols between 64-multidetector computed tomography (MDCT) and 320-MDCT. The cardiac QRM phantoms (1 small size a
Publikováno v:
Journal of Medical and Biological Engineering. 36:96-104
Trabecular bone morphological parameter (TMP) analysis with micro computed tomography (micro-CT) has been used to evaluate the risk of fracture of osteoporosis in small animals. Many researchers have pointed out the drawback of making decisions based
Publikováno v:
IFMBE Proceedings ISBN: 9789811075537
Severe ring artifacts in cone-beam micro-CT degrade image quality and usually cause error recognition during image-based-observer study or computed-aid-diagnosis (CAD). It causes wrong values, such as size of the tumor. The aim of this study was to d
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ec58b36fccf4e0c617337501e5e14263
https://doi.org/10.1007/978-981-10-7554-4_44
https://doi.org/10.1007/978-981-10-7554-4_44
Autor:
Jyh Cheng Chen, Tzu-Chien Hsiao, Woei Chyn Chu, Shih Huan Tu, Chih Wei Kuo, Angela Liu, Chia Jui Hsieh, Ya Chen Chen, Wen Hsiang Chou, Shih Chun Jin
Publikováno v:
Sensors, Vol 18, Iss 12, p 4458 (2018)
Sensors (Basel, Switzerland)
Sensors
Volume 18
Issue 12
Sensors (Basel, Switzerland)
Sensors
Volume 18
Issue 12
Limited-angle iterative reconstruction (LAIR) reduces the radiation dose required for computed tomography (CT) imaging by decreasing the range of the projection angle. We developed an image-quality-based stopping-criteria method with a flexible and i