Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Shervin Ayati"'
Publikováno v:
IEEE Transactions on Biomedical Engineering. 55:1072-1081
During cardiac arrest emergencies, lay rescuers are required to manually check the patient's carotid pulse after the delivery of defibrillation shocks to assess the cardiac resuscitation progress of the patient. As a more automated way of monitoring
Autor:
Patrick J. Tchou, David Schwartzman, Steven M. Markowitz, Suneet Mittal, Bruce B. Lerman, Doris Cavlovich, David J. Slotwiner, Marc A. Scheiner, Shervin Ayati, Kenneth M. Stein
Publikováno v:
Circulation. 101:1282-1287
Background —Clinical studies have shown that biphasic shocks are more effective than monophasic shocks for ventricular defibrillation. The purpose of this study was to compare the efficacy of a rectilinear biphasic waveform with a standard damped s
Autor:
Hugh Calkins, Edward V. Platia, John M. Miller, Kenneth M. Stein, Bruce B. Lerman, David Schwartzman, Steven M. Markowitz, David J. Slotwiner, Bradley P. Knight, Shervin Ayati, Fred Morady, Ruey J. Sung, Patrick J. Tchou, Suneet Mittal, J. Marcus Wharton, Doris Cavlovich
Publikováno v:
Journal of the American College of Cardiology. 34(5):1595-1601
OBJECTIVES We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND Multiple studies have shown that f
Autor:
Heidrun Losert, Moritz Haugk, Danica Krizanac, Fritz Sterz, Christoph Testori, Shervin Ayati, Andrea Zeiner, Jasper Klewer, Michael Holzer
Publikováno v:
Resuscitation. 81(7)
Aim of the study To investigate if body temperature as measured with a prototype of a non-invasive continuous cerebral temperature sensor using the zero-heat-flow method to reflect the oesophageal temperature (core temperature) during mild therapeuti
Autor:
Todd M. Larabee, Charles M. Little, Scott Alan Wuthrich, Michael Nakagawa, Balasundar Iyyavu Raju, John Petruzzello, Ramon Quido Erkamp, Eric Cohen-Solal, Shervin Ayati
Publikováno v:
The American journal of emergency medicine. 29(9)
Objective To determine if a hands-free, noninvasive Doppler ultrasound device can reliably detect low-flow cardiac output by measuring carotid artery blood flow velocities. We compared the ability of observers to detect carotid artery flow velocity d
Publikováno v:
IET 3rd International Conference MEDSIP 2006. Advances in Medical, Signal and Information Processing.
Early defibrillation is critical for successful resuscitation of a sudden cardiac arrest patient. Defibrillators currently do not assess the patient's heartbeat or blood circulation and the responder has to manually check for the pulse, a procedure k
Biphasic energy selection for transthoracic cardioversion of atrial fibrillation. The BEST AF Trial.
Autor:
Glover, B. M., Walsh, S. J., Mccann, C. J., Moore, M. J., Manoharan, G., Dalzell, G. W. N., McAllister, A., McClements, B., McEneaney, D. J., Trouton, T. G., Mathew, T. P., Adgey, A. A. J.
Publikováno v:
Heart; Jul2008, Vol. 94 Issue 7, p884-887, 4p, 1 Diagram, 1 Chart
Publikováno v:
IEEE Transactions on Biomedical Engineering; Mar2008, Vol. 55 Issue 3, p1072-1081, 10p, 4 Black and White Photographs, 1 Chart, 10 Graphs
Publikováno v:
Academic Emergency Medicine; May2007 Supplement 1, Vol. 14, pS7-S211, 205p
Autor:
Walsh, Simon J., McCarty, David, McClelland, Anthony J.J., Owens, Colum G., Trouton, Tom G., Harbinson, Mark T., O'Mullan, Siobhan, McAllister, Andrew, McClements, Brian M., Stevenson, Mike, Dalzell, Gavin W.N., Adgey, A.A. Jennifer
Publikováno v:
European Heart Journal; Jul2005, Vol. 26 Issue 13, p1298-1302, 5p