Zobrazeno 1 - 10
of 37
pro vyhledávání: '"Shaole Wu"'
Publikováno v:
Journal of Analytical Atomic Spectrometry. 14:939-946
A microwave-assisted HNO 3 -HF digestion system was explored for the total dissolution of biological plant and grain materials followed by multi-elemental determination using ICP-MS, in order to improve the low recoveries of several elements observed
Publikováno v:
Journal of Analytical Atomic Spectrometry. 12:797-806
The closed-vessel microwave digestion of four plant standard reference materials (SRMs) and two grain reference materials (RMs) in nitric acid or in a mixture of nitric acid and hydrogen peroxide was explored for the direct determination of 26 elemen
Publikováno v:
J. Anal. At. Spectrom.. 11:287-296
The microwave-assisted conventional HNO3–HF–H2O2–H3BO3 digestion system has been explored for direct ICP-MS analysis of total metals in silicon-containing solid samples. In closed Teflon PFA vessels under microwave heating with temperature/pres
Autor:
Norman J. Dovichi, Shaole Wu
Publikováno v:
Talanta. 39:173-178
Capillary zone electrophoresis, when combined with laser-induced fluorescence, is a very powerful technique for the separation and determination of minute amounts of labeled amino acids. This paper presents the determination of the fluorescein thiohy
Autor:
Norman J. Dovichi, Da Yong Chen, Ronda. Grey, Harold Swerdlow, Shaole Wu, Heather R. Harke, Jian Zhong Zhang, Carl. Fuller
Publikováno v:
Analytical Chemistry. 63:2835-2841
Capillary gel electrophoresis is demonstrated for the four-spectral-channel sequencing technique of Smith, the two-spectral-channel sequencing technique of Prober, and the one-spectral-channel sequencing technique of Richardson and Tabor. Sequencing
Publikováno v:
Journal of Chromatography A. 516:61-67
Capillary polyacrylamide gel electrophoresis separation of dideoxycytidine chain-terminated DNA fragments is reported. A post-column laser-induced fluorescence detector based on the sheath flow cuvette was used to minimize background signals due to l
Publikováno v:
Analytical Chemistry. 62:496-503
Les previsions theoriques et les resultats experimentaux demontrent que le type de detecteur utilise contribue de facon negligeable a l'efficacite de la separation. On obtient une separation avec plus de 2,5×10 6 plateaux theoriques pour des substan
Autor:
Norman J. Dovichi, Shaole Wu
Publikováno v:
Journal of Applied Physics. 67:1170-1182
Fresnel diffraction theory is combined with a three‐dimensional temperature model to predict accurately the beam intensity profile produced by a steady‐state thermal lens in 250‐μm liquid films. In the comparison of theory and data, the optica
Publikováno v:
Electrophoresis. 11:777-780
Capillary zone electrophoresis is employed for the separation and analysis of both fluorescein thiohydantoin and dimethylaminoazobenzene thiohydantoin derivatives of amino acids. Detection of minute amounts of these amino acid derivatives is an impor