Publikováno v:
Energy Reports, Vol 9, Iss , Pp 249-258 (2023)
During the fault of the wind power collection line of the MMC-HVDC system, the amplitude of the fault current may be limited due to the control of the converter, which leads to the severe limitation of traditional protection. In this paper, based on
Externí odkaz:
https://doaj.org/article/bd18d3af72f14d3fb08df478f7efc20b
Publikováno v:
Energy Reports, Vol 9, Iss , Pp 266-274 (2023)
An isolated power grid (IPG) lacks the support of the external power grid, and a single generator or load accounts for a large proportion of the total capacity. Once transient angle instability, the generator and load shedding is not effectively. Pha
Externí odkaz:
https://doaj.org/article/232f9c162cb1472da8b3fff779a949e4
Publikováno v:
IET Power Electronics, Vol 16, Iss 1, Pp 26-36 (2023)
Abstract Phase sequence exchange (PSE) is a recently developed emergency control technology that uses power electronic devices to quickly change the original phase sequence connection mode of the transmission line from A‐A', B‐B', and C‐C' to A
Externí odkaz:
https://doaj.org/article/5b9ade70c30c4cfe9824943c2c43cc4e
Publikováno v:
IET Generation, Transmission & Distribution, Vol 16, Iss 22, Pp 4652-4661 (2022)
Abstract Concerning the distance protection steady‐state over‐reach or under‐reach caused by the transition resistance, a novel distance protection scheme based on transient information is proposed. First, multiple fault features are extracted
Externí odkaz:
https://doaj.org/article/32a5a33437ae49cba1f6ac0591f8e6e5
Publikováno v:
IET Power Electronics, Vol 15, Iss 5, Pp 412-421 (2022)
Abstract Phase sequence exchange (PSE) is an emerging emergency control method for power systems. However, PSE will generate impulse current and voltage. In this research, to suppress the impulse of PSE, a phase control method for zero‐current open
Externí odkaz:
https://doaj.org/article/860ce12fe1534157afe8dbaa43fa31a0
Publikováno v:
The Journal of Engineering, Vol 2022, Iss 4, Pp 447-451 (2022)
Abstract This letter proposes a novel phase sequence exchange (PSE) device. When the generator loses synchronization and the power angle gradually increases, the primary side of the contact line is disconnected and quickly connected in a staggered ph
Externí odkaz:
https://doaj.org/article/b1aba370ec764f459c89ac83d7682c09
Autor:
Yanqing Ge, Shaofeng Huang, Yiming Hu, Lei Zhang, Ling He, Sebastian Krajewski, Michael Ortiz, Yinghua Jin, Wei Zhang
Publikováno v:
Nature Communications, Vol 12, Iss 1, Pp 1-10 (2021)
Alkyne metathesis catalysts usually suffer from high moisture/air sensitivity, which limit their wide applicability. Here, the authors report efficient alkyne metathesis catalysts that can operate under open-air conditions with a broad functional gro
Externí odkaz:
https://doaj.org/article/3adb528a6c61490cbcf6df09bfaa75c1
Autor:
Qi Zhang, Jun Zhu, Xin Yu, Shaofeng Huang, Xinyu Zhang, Shenbao Zhang, Rangjian Qiu, Evgenios Agathokleous
Publikováno v:
Environmental Research Letters, Vol 18, Iss 11, p 114002 (2023)
In China, more than two-thirds of protected cultivation occurs in low-tech facilities with limited ability to withstand adverse weather conditions. However, the specific meteorological factors that hinder facility agriculture production in various lo
Externí odkaz:
https://doaj.org/article/5c8ca019abe74d388ce0c2ade556a0db
Publikováno v:
Energies, Vol 15, Iss 21, p 8014 (2022)
Power angle stability of power systems is one of the main factors which restricts the power transmission capacity. In order to prevent the power angle instability of power systems, phase sequence exchange (PSE) is a recently developed emergency contr
Externí odkaz:
https://doaj.org/article/dd6c39530b774bde8ffd77ee0e741c87
Publikováno v:
IEEE Access, Vol 7, Pp 93002-93009 (2019)
AC transmission systems are often affected by stability issues. During the design phase of such systems, their ability to cope with the various kinds of disturbance is taken into consideration, however, sudden large disturbances may still result in p
Externí odkaz:
https://doaj.org/article/a8720ba7651d475f9c33976048ed7273