Publikováno v:
Energies, Vol 14, Iss 5, p 1379 (2021)
In power systems, high renewable energy penetration generally results in conventional synchronous generators being displaced. Hence, the power system inertia reduces, thus causing a larger frequency deviation when an imbalance between load and genera
Externí odkaz:
https://doaj.org/article/2c7e6efd9549423bb34637e1cccf849e
Publikováno v:
Applied Sciences, Vol 8, Iss 11, p 2059 (2018)
The doubly-fed induction generator has significant features compared to the fixed speed wind turbine, which has popularised its application in power systems. Due to partial rated back-to-back converters in the doubly-fed induction generator, fault ri
Externí odkaz:
https://doaj.org/article/0973575ce0cf4ac7b42ffb14623da2f6
Publikováno v:
IEEE Transactions on Industry Applications. 55:2021-2032
A simple conventional dc chopper is employed to protect the doubly-fed induction generator (DFIG) from overvoltage; however, it is not capable to keep the transient overcurrent in an acceptable level in stator and rotor sides. Therefore, an effective
Publikováno v:
Energies, Vol 14, Iss 1379, p 1379 (2021)
Energies; Volume 14; Issue 5; Pages: 1379
Energies; Volume 14; Issue 5; Pages: 1379
In power systems, high renewable energy penetration generally results in conventional synchronous generators being displaced. Hence, the power system inertia reduces, thus causing a larger frequency deviation when an imbalance between load and genera
Publikováno v:
2019 9th International Conference on Power and Energy Systems (ICPES).
In this paper, the coordinated operation of fault current limiter (FCL) and inverter-interfaced load (IIL) is studied when providing frequency ancillary service (FCAS) during a fault condition. When the fault occurs as a contingency event, the voltag
Frequency Response of Synchronous Generators and Battery Energy Storage Systems: A Comparative Study
Publikováno v:
2019 29th Australasian Universities Power Engineering Conference (AUPEC).
In this paper, a comparison of power system frequency response is conducted for a simple modelled power system with primary frequency control being provided either by synchronous generators or by inverter-based Battery Energy Storage (BES) systems. M
Publikováno v:
International Journal of Electrical Power & Energy Systems. 95:653-663
Recently penetration level of converter-interfaced distributed generation (DG) systems has been increased in utility and will be more so in the future. To avoid grid instability, converter-interfaced DG should have low voltage ride through (LVRT) cap
Autor:
Kashem M. Muttaqi, Seyed Behzad Naderi, Mehrdad Tarafdar Hagh, Michael Negnevitsky, Amin Jalilian
Publikováno v:
International Journal of Electrical Power & Energy Systems. 86:104-119
Doubly-fed induction generator (DFIG)-based wind turbines utilise small-scale voltage sourced converters with a limited overcurrent withstand capability, which makes the DFIG-based wind turbines very vulnerable to grid faults. Often, modern DFIG syst
Autor:
Seyed Behzad Naderi, Michael Negnevitsky, Mehrdad Tarafdar Hagh, Amin Jalilian, Kashem M. Muttaqi
Publikováno v:
IET Renewable Power Generation. 11:313-324
Doubly fed induction generator (DFIG) based wind turbines are sensitive to grid faults due to utilising small-scale rotor side converter (RSC). The application of crowbar protection to improve the fault ride-through (FRT) capability of the DFIG conve
Autor:
Kashem M. Muttaqi, Amin Jalilian, Michael Negnevitsky, Mehrdad Tarafdar Hagh, Seyed Behzad Naderi
Publikováno v:
IEEE Transactions on Industry Applications. 53:538-548
This paper proposes an optimum resistive type fault current limiter (OR-FCL) as an efficient solution to achieve maximum fault ride-through (FRT) capability of fixed-speed wind turbines (FSWT) during various grid faults. In this paper, a dedicated co