Zobrazeno 1 - 10
of 35
pro vyhledávání: '"Sevan Goenezen"'
Publikováno v:
Acta Polytechnica, Vol 61, Iss 5, Pp 661-671 (2021)
Existing biodegradable Magnesium Alloy Stents (MAS) have several drawbacks, such as high restenosis, hasty degradation, and bulky cross-section, that limit their widespread application in a current clinical practice. To find the optimum stent with th
Externí odkaz:
https://doaj.org/article/a8c65107099646099c99fd9a95a4a2e7
Publikováno v:
Sensors, Vol 18, Iss 2, p 384 (2018)
The authors wish to correct Figures 12 and 14 in their paper published in Sensors [1], doi:10.3390/s17051075, http://www.mdpi.com/1424-8220/17/5/1075[...]
Externí odkaz:
https://doaj.org/article/715b393b6d93402892743a99fc2ac430
Publikováno v:
Sensors, Vol 17, Iss 5, p 1075 (2017)
We present a non-destructive approach to sense inclusion objects embedded in a solid medium remotely from force sensors applied to the medium and boundary displacements that could be measured via a digital image correlation system using a set of came
Externí odkaz:
https://doaj.org/article/329709f6ca0442afa872958d34314760
Publikováno v:
PLoS ONE, Vol 9, Iss 7, p e101353 (2014)
An abdominal aortic aneurysm is a pathological dilation of the abdominal aorta, which carries a high mortality rate if ruptured. The most commonly used surrogate marker of rupture risk is the maximal transverse diameter of the aneurysm. More recent s
Externí odkaz:
https://doaj.org/article/84f848c17f2e40ad9013bdc1e06925df
Publikováno v:
Journal of Cardiovascular Development and Disease, Vol 3, Iss 1, p 1 (2015)
We analyzed heart wall motion and blood flow dynamics in chicken embryos using in vivo optical coherence tomography (OCT) imaging and computational fluid dynamics (CFD) embryo-specific modeling. We focused on the heart outflow tract (OFT) region of d
Externí odkaz:
https://doaj.org/article/66574fb813ca45fb900849053a691824
Publikováno v:
Acta Polytechnica, Vol 61, Iss 5, Pp 661-671 (2021)
Existing biodegradable Magnesium Alloy Stents (MAS) have several drawbacks, such as high restenosis, hasty degradation, and bulky cross-section, that limit their widespread application in a current clinical practice. To find the optimum stent with th
Publikováno v:
The Journal of Strain Analysis for Engineering Design. 57:445-458
Polycrystalline materials consist of grains (crystals) oriented at different angles resulting in a heterogeneous and anisotropic mechanical behavior at that micro-length scale. In this study, a novel method is proposed for the first time to determine
Publikováno v:
Computational Mechanics. 67:1581-1599
The identification of nonhomogeneous elastic property distributions has been traditionally achieved with well acknowledged optimization based inverse approaches, but when full-field displacement measurements are available, the virtual fields method (
Publikováno v:
Inverse Problems in Science and Engineering. 28:1493-1512
The unloaded configuration of a body without residual stresses is generally used as the starting point to compute the displacement field but may be unknown for some applications. In this paper, we ...
Publikováno v:
International Journal of Solids and Structures. 165:50-62
Due to wide applications of hyper-viscoelastic material models in medicine and industry, many researchers have focused on determination of the parameters of these models. In problems for identification of material parameters of hyper-elastic and hype