Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Sergey V. Beiden"'
Publikováno v:
Medical Decision Making. 24:561-572
The multiple-reader, multiple-case (MRMC) approach to receiver operating characteristic (ROC) analysis is becoming the dominant assessment paradigm in medical imaging. Its most common version involves having many readers read every patient case in th
Autor:
Sergey V. Beiden, Stephen L. Hillis, Hae Hiang Song, Kevin S. Berbaum, Robert F. Wagner, Hemant Ishwaran, Nancy A. Obuchowski
Publikováno v:
Academic Radiology. 11:980-995
Rationale and objectives Several statistical methods have been developed for analyzing multireader, multicase (MRMC) receiver operating characteristic (ROC) studies. The objective of this article is to increase awareness of these methods and determin
Autor:
Samuel G. Armato, David Gur, Berkman Sahiner, J W Sayre, Nicholas Petrick, Geoffrey McLennan, Michael F. McNitt-Gray, Robert F. Wagner, Heang Ping Chan, Sergey V. Beiden, Lori E. Dodd, Charles E. Metz
Publikováno v:
Academic Radiology. 11:462-475
Cancer of the lung and bronchus is the leading fatal malignancy in the United States. Five-year survival is low, but treatment of early stage disease considerably improves chances of survival. Advances in multidetector-row computed tomography technol
Publikováno v:
Academic Radiology. 9:1264-1277
In the last 2 decades major advances have been made in the field of assessment methods for medical imaging and computer–assist systems through the use of the paradigm of the receiver operating characteristic (ROC) curve. In the most recent decade t
Autor:
Robert F. Wagner, Shih-Chung Ben Lo, Xin-Wei Xu, Robert M. Nishikawa, Kunio Doi, Matthew L. Freedman, Sergey V. Beiden
Publikováno v:
Academic Radiology. 9:1036-1043
Rationale and Objectives The authors analyzed two methods for arranging the temporal sequencing of unaided versus computer-assisted reading in multiple-reader, multiple-case receiver operating characteristic studies of detection of solitary pulmonary
Publikováno v:
Academic Radiology. 8:605-615
Rationale and Objectives Several of the authors have previously published an analysis of multiple sources of uncertainty in the receiver operating characteristic (ROC) assessment and comparison of diagnostic modalities. The analysis assumed that the
Publikováno v:
Academic Radiology. 8:328-334
Rationale and Objectives Several authors have encouraged the use of a quasi-continuous rating scale for data collection in receiver operating characteristic (ROC) curve analysis of diagnostic modalities, rather than rating scales based on five to sev
Publikováno v:
Academic Radiology. 7:341-349
Rationale and Objectives. The purpose of this study was to develop an alternative approach to random-effects, receiver operating characteristic analysis inspired by a general formulation of components-of-variance models. The alternative approach is a
Autor:
Nancy A, Obuchowski, Sergey V, Beiden, Kevin S, Berbaum, Stephen L, Hillis, Hemant, Ishwaran, Hae Hiang, Song, Robert F, Wagner
Publikováno v:
Academic radiology. 11(9)
Several statistical methods have been developed for analyzing multireader, multicase (MRMC) receiver operating characteristic (ROC) studies. The objective of this article is to increase awareness of these methods and determine if their results are co
Publikováno v:
Medical Imaging 2003: Image Perception, Observer Performance, and Technology Assessment.
The dialog among investigators in academia, industry, NIH, and the FDA has grown in recent years on topics of historic interest to attendees of these SPIE sub-conferences on Image Perception, Observer Performance, and Technology Assessment. Several o