Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Serge Camou"'
Autor:
Serge Camou
Publikováno v:
Sensors, Vol 15, Iss 7, Pp 16358-16371 (2015)
Towards the noninvasive and continuous monitoring of blood glucose levels, we chose the continuous-wave photoacoustic (CW-PA) technique and developed the optical power balance shift (OPBS) method. However, operating with optical wavelengths in the ne
Externí odkaz:
https://doaj.org/article/f98b1b1b8a3a474db69ad14527a472be
Autor:
Emi Tamechika, Serge Camou
Publikováno v:
Sensors and Actuators B: Chemical. 189:224-229
Towards the development of a sensor dedicated to noninvasive and continuous blood glucose level monitoring, we developed a protocol called optical power balance shift (OPBS) based on a continuous-wave photoacoustic technique using a dual wavelength e
Autor:
Tsuneyuki Haga, Jun-ichi Takahashi, Tsutomu Horiuchi, Michiko Seyama, Toru Miura, Yuzuru Iwasaki, Serge Camou
Publikováno v:
Sensors and Actuators B: Chemical. 173:354-360
We developed a patterned cellulose membrane for surface plasmon resonance (SPR) measurement that works as a capillary force inducing material to provide liquid flow and as a support for antibody immobilization. The patterned cellulose membrane was di
Publikováno v:
Analytical Chemistry. 84:4718-4724
Toward the achievement of noninvasive and continuous monitoring of blood glucose level, we developed a new measurement method based on the continuous-wave photoacoustic (CW-PA) technique and performed the first validation in vitro with calibrated aqu
Publikováno v:
Procedia Chemistry. 1(1):1495-1498
This paper describes a new portable aqueous benzene sensor that combines UV-spectroscopy detection and benzene extraction from the liquid to gas phase based on pervaporation through a silicone tube. Pervaporation through a silicone membrane provides
Publikováno v:
Sensors and Actuators B: Chemical. 132:601-607
A new, easy-to-use portable sensor dedicated to the detection of benzene diluted in aqueous solution is presented. By means of ambient air bubbling through the liquid sample, the benzene compound is first transferred to the vapor phase, and a high-ef
Publikováno v:
2015 IEEE SENSORS.
Glucose sensitivity of the optical power balance shift (OPBS) method, which we previously proposed, has been improved by numerical correction of laser drift and by data analysis. The detection limit is determined by the stability and resolution of in
Publikováno v:
2013 IEEE SENSORS.
This paper describes the design, fabrication, and testing of a fluidic cell, i.e., the phantom, dedicated to the noninvasive characterization of aqueous solutions based on continuous wave photoacoustic (CW-PA) protocols. The proposed fabrication meth
Publikováno v:
2012 IEEE Sensors.
Over the last few years, we have developed two protocols based on the continuous-wave photoacoustic (CW-PA) technique and dedicated much effort to exploring the noninvasive and continuous monitoring of blood glucose levels. So far, all of the experim
Publikováno v:
2011 IEEE SENSORS Proceedings.
Towards the design of a non-invasive and continuous blood glucose sensor, we chose the continuous-wave photoacoustic (CW-PA) protocol and first developed the frequency shift (FS) method. However, despite linear dependence versus aqueous glucose conce