Publikováno v:
IEEE Transactions on Nuclear Science. 43:2320-2325
Digital X-ray imaging detectors designed for soft X-rays (1 to 50 keV) are significant for medical mammography, dental radiography, microradiography, and microtomography. Detector designs involve either direct absorption of X-rays in solid state devi
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 353:312-315
An analytic model for the performance of cone beam microtomography is described. The maximum power of a microfocus X-ray source is assumed to be approximately proportional to the focal spot size. Radiation flux penetrating the specimen is predicted b
Publikováno v:
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.
The authors have previously used volumetric computed tomography for imaging bone specimens with approximately 50 micrometer resolution. Three dimensional measurement methods which can determine bone density to within one percent for detail as small a
Publikováno v:
IEEE Conference on Nuclear Science Symposium and Medical Imaging.
A method using high-magnification, high-resolution, digital radiographs of a precise edge to obtain quantitative estimates of focal spot dimensions has been developed. The X-ray intensity distribution is determined from the edge response. The method
Autor:
James T. Dobbins III, Sean M. Hames, Bruce H. Hasegawa, Timothy R. DeGrado, James A. Zagzebski, Richard Frayne
Publikováno v:
The Measurement, Instrumentation and Sensors Handbook on CD-ROM ISBN: 9780849383472
Measurement, Instrumentation, and Sensors Handbook ISBN: 9781315217444
Measurement, Instrumentation, and Sensors Handbook ISBN: 9781315217444
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::63e2efad098d2983bba79c719bdc1312
https://doi.org/10.1201/9780415876179.ch79
https://doi.org/10.1201/9780415876179.ch79
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 48(10-12)
A system for 3D cone beam computed tomography has been developed, consisting of a microfocus x-ray source and x-ray image intensifier coupled to a CCD camera. Full width at half maximum resolving power has been experimentally measured to be 70 μm wh
Effect of direct x-ray interaction in the photodetector on image noise for a CCD/scintillator system
Publikováno v:
Medical Imaging 1996: Physics of Medical Imaging.
Digital x-ray imaging detectors for soft x-rays (1 to 50 keV) are significant for medical mammography, dental radiography, microradiography, x-ray diffraction, and x-ray telescope applications. For systems in which a scintillator is optically coupled
Publikováno v:
SPIE Proceedings.
Point projection microradiography has established value for imaging large, wet, opaque, and intact specimens in 2D projection views. We have developed a 3D microtomography system by combining the principles of microradiography with computed tomograph
Publikováno v:
SPIE Proceedings.
X-ray microcomputed tomograms with resolution of 50 microns or better have been obtained at several research centers by using either synchrotron or microfocus x-ray sources. Full 3D reconstructions have been obtained in these laboratories on specimen
Publikováno v:
Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.
The resolution of 2D imaging systems is frequently described by experimental estimates of the point, line, or edge spread function. It is shown that a response function across the normal to a boundary between two homogeneous volumes can provide a mea