Publikováno v:
2022 IEEE 7th Southern Power Electronics Conference (SPEC).
Autor:
Sarath B. Tennakoon, Hossein Iman-Eini
Publikováno v:
International Journal of Electrical Power & Energy Systems. 105:330-340
In this paper, the cascaded H-bridge (CHB) multilevel inverter is employed as a grid connected inverter. This kind of inverter has interesting features compared to conventional inverters, including better efficiency, lower THD, lower common mode curr
Autor:
Sarath B. Tennakoon, Monday Ikhide, Sankara Subramanian, Andrzej J. Adamczyk, Hengxu Ha, Alison Griffiths
Publikováno v:
The Journal of Engineering. 2018:1267-1273
This study presents a novel time-domain protection technique for application to DC grids. The technique utilises the power developed by the forward and backward travelling waves produced by a fault to distinguish between internal and external faults.
Publikováno v:
IEEE Transactions on Industry Applications. 53:2840-2851
Modular multilevel converters (MMCs) will be extensively used in the high-voltage direct-current transmission networks because of its superior characteristics over line commutated converter. Increasing the reliability of the MMC is directly related t
Publikováno v:
Renewable Energy and Power Quality Journal
A DC-DC converter suitable for the grid integration of windfarms through a DC grid is presented. The operation is based on the Marx principle where charged capacitors are connected in series and parallel in turn to achieve the voltage transformation.
Publikováno v:
Renewable Energy and Power Quality Journal. 1:540-544
Publikováno v:
2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern Power Electronics Conference (COBEP/SPEC).
This paper presents a transient based protection principle utilising the magnitude of the travelling wave power derivative at only local terminal to formulate a non-unit protection scheme, where the directional transient relay and boundary relay have
Publikováno v:
IAS
Electrical power to data hall critical loads will often be fed via an uninterruptable power supply (UPS) strings. Therefore, fault tolerance of these machines is of pivotal importance for the data centres uptime. The UPS will be in the middle of a co
Autor:
Andrzej J. Adamczyk, Monday Ikhide, Sarath B. Tennakoon, Sankara Subramanian, H. Ha, Alison Griffiths
Publikováno v:
15th IET International Conference on AC and DC Power Transmission (ACDC 2019).
Publikováno v:
Journal of Power Electronics. 16:1743-1751
The increasing demand for high voltage DC grids resulting from the continuous installation of offshore wind farms in the North Sea has led to the concept of multi-terminal direct current (MTDC) grids, which face some challenges. Power (current) flow