Zobrazeno 1 - 10
of 64
pro vyhledávání: '"Sanjay S. Supe"'
Publikováno v:
Journal of Medical Physics, Vol 36, Iss 1, Pp 29-34 (2011)
The goal of the present study was to study the effects of low- and high-energy intensity-modulated photon beams on the planning of target volume and the critical organs in cases of localized prostate tumors in a cohort of 8 patients. To ensure that t
Externí odkaz:
https://doaj.org/article/e4417ecfbb9d433cae3dc0c6882d3e1a
Publikováno v:
Journal of Cancer Research and Therapeutics, Vol 11, Iss 1, Pp 29-36 (2015)
Background: The translation and cultural adaptation of psychometrically tested tools is an essential component of effective evaluation of the intended purpose. The English questionnaire had been designed to measure current status of physiotherapy pra
Publikováno v:
Reports of Practical Oncology & Radiotherapy. 19:151-156
AimTo calibrate Ir-192 high dose rate (HDR) brachytherapy source using different calibration methods and to determine the accuracy and suitability of each method for routine calibrations.BackgroundThe source calibration is an essential part of the qu
Publikováno v:
Technology in Cancer Research & Treatment. 11:141-147
Dosimetric changes caused by the positional uncertainty of centering a small electron cutout to the machine central axis (CAX) of the linear accelerator (linac) were investigated. Six circular cutouts with 4 cm diameter were made with their centres s
Publikováno v:
Indian Journal of Palliative Care, Vol 18, Iss 2, Pp 87-97 (2012)
Indian Journal of Palliative Care
Indian Journal of Palliative Care
Rehabilitation in relation to cancer can be preventative, restorative, supportive, and palliative. It is recognized that patients may have rehabilitation needs throughout their care pathway. The role of physiotherapy in the cancer rehabilitation is l
Autor:
Sanjay S. Supe, Carlos Esquivel, Ravikumar Manickam, Sotirios Stathakis, Nikos Papanikolaou, Varatharaj Chandraraj
Publikováno v:
Journal of Applied Clinical Medical Physics
For intensity‐modulated radiation therapy, evaluation of the measured dose against the treatment planning calculated dose is essential in the context of patient‐specific quality assurance. The complexity of volumetric arc radiotherapy delivery at
Publikováno v:
Polish Journal of Medical Physics And Engineering. 17:143-151
Physical characteristics of photon beam from a CLINAC-DBX single energy accelerator Commissioning beam data are treated as a reference and ultimately used by treatment planning systems, therefore, it is vitally important that the collected data are o
Autor:
Meenakshi Nagarajan, V Nagarajan, KN Govindarajan, Sundaram Thangavelu, Sanjay S. Supe, S. K. V. Jayakumar
Publikováno v:
Journal of Medical Physics, Vol 36, Iss 1, Pp 29-34 (2011)
Journal of Medical Physics / Association of Medical Physicists of India
Journal of Medical Physics / Association of Medical Physicists of India
The goal of the present study was to study the effects of low- and high-energy intensity-modulated photon beams on the planning of target volume and the critical organs in cases of localized prostate tumors in a cohort of 8 patients. To ensure that t
Consistency and reproducibility of the VMAT plan delivery using three independent validation methods
Autor:
Sanjay S. Supe, Carlos Esquivel, Sotirios Stathakis, Varatharaj Chandraraj, Nikos Papanikolaou, Ravikumar Manickam
Publikováno v:
Journal of Applied Clinical Medical Physics
The complexity of VMAT delivery requires new methods and potentially new tools for the commissioning of these systems. It appears that great consideration is needed for quality assurance (QA) of these treatments since there are limited devices that a
Publikováno v:
Reports of Practical Oncology & Radiotherapy. 15(5):125-131
Background Intensity modulated radiotherapy (IMRT) is being used to treat carcinoma of cervix (Ca Cx). Integral dose to normal tissue and increased leakage are the concern about IMRT. 6 MV photon beam is a good choice of energy for Ca Cx IMRT treatme