Autor:
Federica Vurchio, Pietro Ursi, Francesco Orsini, Andrea Scorza, Rocco Crescenzi, Salvatore A. Sciuto, Nicola P. Belfiore
Publikováno v:
Applied Sciences, Vol 9, Iss 9, p 1901 (2019)
Micro Electro Mechanical Systems (MEMS)-Technology based micro mechanisms usually operate within a protected or encapsulated space and, before that, they are fabricated and analyzed within one Scanning Electron Microscope (SEM) vacuum specimen chambe
Externí odkaz:
https://doaj.org/article/670298ade9d947b29d922ab0e4411100
Autor:
Federico Filippi, Giorgia Fiori, Annalisa Genovesi, Massimiliano Barletta, Matteo Lancini, Mauro Serpelloni, Andrea Scorza, Salvatore Andrea Sciuto
Publikováno v:
Sensors, Vol 24, Iss 23, p 7725 (2024)
Wearable strain sensors are widespread in many fields, including the biomedical field where they are used for their stretchability and ability to be applied to non-regular surfaces. The study of the propagation speed of the pressure wave generated by
Externí odkaz:
https://doaj.org/article/b0814b8c528e490b842e688aceff6501
Publikováno v:
Sensors, Vol 24, Iss 19, p 6491 (2024)
Quality assessment of ultrasound medical systems is a demanding task due to the high number of parameters to quantify their performance: in the present study, a Kiviat diagram-based integrated approach was proposed to effectively combine the contribu
Externí odkaz:
https://doaj.org/article/2da30282e6fd46f8a7138a07edd1b3fe
Publikováno v:
Metrology, Vol 2, Iss 3, Pp 360-386 (2022)
Arterial simulators are a useful tool to simulate the cardiovascular system in many different fields of application and to carry out in vitro tests that would constitute a danger when performed in in vivo conditions. In the literature, a thriving ser
Externí odkaz:
https://doaj.org/article/ea74cb49fc844306a453abca016e476c
Publikováno v:
Actuators, Vol 12, Iss 7, p 261 (2023)
The introduction of smart materials will become increasingly relevant as biomedical technologies progress. Smart materials sense and respond to external stimuli (e.g., chemical, electrical, mechanical, or magnetic signals) or environmental circumstan
Externí odkaz:
https://doaj.org/article/863a1845e5a14559986e08884bdb0862
Publikováno v:
Sensors, Vol 23, Iss 11, p 5005 (2023)
The increasing incidence of cardiovascular diseases (CVDs) is reflected in additional costs for healthcare systems all over the world. To date, pulse transit time (PTT) is considered a key index of cardiovascular health status and for diagnosis of CV
Externí odkaz:
https://doaj.org/article/9b0f430eb23d428782a30e68d19e60da
Autor:
Fabio Fuiano, Giorgia Fiori, Andrea Scorza, Maurizio Schmid, Silvia Conforto, Salvatore Andrea Sciuto
Publikováno v:
Measurement: Sensors, Vol 18, Iss , Pp 100240- (2021)
Nowadays, in both scientific and medical communities, Pulse Wave Velocity (PWV) is commonly considered as a predicting factor of cardiovascular diseases. Such issue leads to the necessity of accurate PWV measurements as PWV non-local assessment is cu
Externí odkaz:
https://doaj.org/article/71e93bc99c8e4c2db486a94218ba6349
Autor:
Giorgia Fiori, Andrea Scorza, Maurizio Schmid, Jan Galo, Silvia Conforto, Salvatore Andrea Sciuto
Publikováno v:
Measurement: Sensors, Vol 18, Iss , Pp 100245- (2021)
Color Doppler (CD) is one of the most used ultrasound (US) Doppler techniques as it allows the 2D representation of blood flow. Even if a clarification on whether such technique provides qualitative or quantitative diagnostic information on velocity
Externí odkaz:
https://doaj.org/article/c22887c4e00a4f66a6c04b7e5332336a
Autor:
Giorgia Fiori, Andrada Pica, Salvatore Andrea Sciuto, Franco Marinozzi, Fabiano Bini, Andrea Scorza
Publikováno v:
Sensors, Vol 22, Iss 24, p 9868 (2022)
Color Doppler (CD) imaging is widely used in diagnostics since it allows real-time detection and display of blood flow superimposed on the B-mode image. Nevertheless, to date, a shared worldwide standard on Doppler equipment testing is still lacking.
Externí odkaz:
https://doaj.org/article/d3435c1b42134409b877f204f15330d0
Autor:
Giorgia Fiori, Fabio Fuiano, Maurizio Schmid, Silvia Conforto, Salvatore A. Sciuto, Andrea Scorza
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 72:1-8
Depth of penetration (DOP) has been investigated in the scientific literature as an informative parameter able to monitor over time both the sensitivity and the general performance of ultrasound (US) diagnostic systems. In common practice, this param