Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Salma Ajraoui"'
Publikováno v:
NMR in Biomedicine. 25:389-399
In hyperpolarised 3He lung MRI with constant flip angles, the transverse magnetisation decays with each RF excitation imposing a k-space filter on the acquired data. For radial data acquired in an angularly-sequential order, this filter causes streak
Autor:
Helen Marshall, Jim M. Wild, Salma Ajraoui, Juan Parra-Robles, Martin H. Deppe, Matthew Clemence
Publikováno v:
NMR in Biomedicine. 25:44-51
In imaging of human lungs with hyperpolarised noble gases, measurements of apparent diffusion coefficient (ADC) and relaxation time provide valuable information for the assessment of lung microstructure. In this work, a sequence was developed for int
Publikováno v:
Magnetic Resonance in Medicine. 65:1075-1083
Washout of inert gases is a measure of pulmonary function well-known in lung physiology. This work presents a method combining inert gas washout and spatially resolved imaging using hyperpolarized 3He, thus providing complementary information on lung
Autor:
Salma Ajraoui, Helen Marshall, Jim M. Wild, Martin H. Deppe, Juan Parra-Robles, Rob H. Ireland, S. R. Parnell
Publikováno v:
NMR in Biomedicine. 24:130-134
The development of hybrid medical imaging scanners has allowed imaging with different detection modalities at the same time, providing different anatomical and functional information within the same physiological time course with the patient in the s
Publikováno v:
Journal of Magnetic Resonance. 204:228-238
Models of lung acinar geometry have been proposed to analytically describe the diffusion of (3)He in the lung (as measured with pulsed gradient spin echo (PGSE) methods) as a possible means of characterizing lung microstructure from measurement of th
Publikováno v:
Magnetic Resonance in Medicine. 63:1059-1069
In this work, the application of compressed sensing techniques to the acquisition and reconstruction of hyperpolarized (3)He lung MR images was investigated. The sparsity of (3)He lung images in the wavelet domain was investigated through simulations
Autor:
Ralph Hashoian, Xiaojun Xu, Martin H. Deppe, Juan Parra-Robles, S. R. Parnell, Graham Norquay, Helen Marshall, Salma Ajraoui, Paul D. Griffiths, Jim M. Wild
Publikováno v:
Magnetic resonance in medicine. 68(6)
In this study, the signal-to-noise ratio of hyperpolarized (129)Xe human lung magnetic resonance imaging was compared at 1.5 T and 3 T. Experiments were performed at both B(0) fields with quadrature double Helmholtz transmit-receive chest coils of th
Publikováno v:
Magnetic resonance in medicine. 69(2)
Adding prior knowledge to compressed sensing reconstruction can improve image reconstruction. In this work, two approaches are investigated to improve reconstruction of two-dimensional hyperpolarized 3He lung ventilation images using prior knowledge.
Publikováno v:
Magnetic resonance in medicine. 67(2)
The (3)He MR diffusion signal is sensitive to lung microstructure, but it is also affected by the presence of background field inhomogeneities induced by the magnetic susceptibility difference at the air-tissue interface. These susceptibility-induced
Publikováno v:
NMR in biomedicine. 25(2)
In hyperpolarised (3)He lung MRI with constant flip angles, the transverse magnetisation decays with each RF excitation imposing a k-space filter on the acquired data. For radial data acquired in an angularly-sequential order, this filter causes stre