Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Sally A. N. Gowers"'
Autor:
Momen K. Tageldeen, Sally A. N. Gowers, Chi L. Leong, Martyn G. Boutelle, Emmanuel M. Drakakis
Publikováno v:
Journal of NeuroEngineering and Rehabilitation, Vol 17, Iss 1, Pp 1-16 (2020)
Abstract Background Traumatic Brain Injury (TBI) is a leading cause of fatality and disability worldwide, partly due to the occurrence of secondary injury and late interventions. Correct diagnosis and timely monitoring ensure effective medical interv
Externí odkaz:
https://doaj.org/article/6e19fbe6d3534d21868ef888d7fa6bdd
Autor:
Damien K Ming, Saylee Jangam, Sally A N Gowers, Richard Wilson, David M E Freeman, Martyn G Boutelle, Anthony E G Cass, Danny O’Hare, Alison H Holmes
Publikováno v:
BMJ Innovations. 8:87-94
IntroductionDetermination of blood lactate levels supports decision-making in a range of medical conditions. Invasive blood-sampling and laboratory access are often required, and measurements provide a static profile at each instance. We conducted a
Autor:
David Me Freeman, Alison Holmes, Pantelis Georgiou, Anthony E. G. Cass, Danny O'Hare, Sally A. N. Gowers, Timothy M. Rawson, Damien Ming, Pau Herrero
Publikováno v:
The Journal of Infection
Summary A paucity of data describing citizen perceptions of novel technologies, including those containing unsupervised computer-controlled systems is currently available. We explored citizen perceptions of using a microneedle biosensor and automated
Autor:
Nicolas Moser, Yuanqi Hu, Chi Leng Leong, Martyn G. Boutelle, Pantelis Georgiou, Chiara Cicatiello, Sally A. N. Gowers
Publikováno v:
Analytical Chemistry
This work describes an array of 1024 ion-sensitive field-effect transistors (ISFETs) using sensor-learning techniques to perform multi-ion imaging for concurrent detection of potassium, sodium, calcium, and hydrogen. Analyte-specific ionophore membra
Autor:
Vassilios Papalois, Martyn G. Boutelle, Terry Cook, Adeel Aftab, Geoffrey P. Dobson, Karim Hamaoui, Sally A. N. Gowers, Donna Rudd
Publikováno v:
Journal of Surgical Research. 208:219-229
Background The optimal hypothermic machine perfusion (HMP) solution has not yet been developed. An adenosine and lidocaine (AL) solution has been shown to be protective in cardiac preservation. The aim of the present study was to examine a modified A
Autor:
Georgia K Smith, Kirsten Møller, De-Shaine R. K. Murray, Martyn G. Boutelle, Sarah Jeyaprakash, Michelle L. Rogers, Markus Harboe Olsen, Isabelle C. Samper, Michael Karlsson, Sally A. N. Gowers
Publikováno v:
Gowers, S A N, Samper, I C, Murray, D R K, Smith, G K, Jeyaprakash, S, Rogers, M L, Karlsson, M, Olsen, M H, Møller, K & Boutelle, M G 2020, ' Real-time neurochemical measurement of dynamic metabolic events during cardiac arrest and resuscitation in a porcine model ', The Analyst, vol. 145, no. 5, pp. 1894-1902 . https://doi.org/10.1039/C9AN01950B
This work describes a fully-integrated portable microfluidic analysis system for real-time monitoring of dynamic changes in glucose and lactate occurring in the brain as a result of cardiac arrest and resuscitation. Brain metabolites are sampled usin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::10b7f2c287a09a3d8d8f7171433668d1
http://hdl.handle.net/10044/1/76226
http://hdl.handle.net/10044/1/76226
Autor:
Tonghathai Phairatana, Isabelle C. Samper, Martyn G. Boutelle, Thomas Watts, Vassilios Papalois, Chu Wang, Sally A. N. Gowers, Natalie Vallant, Marsilea A. Booth, Bynvant Sandhu
Publikováno v:
Analytical Chemistry
Currently, there is a severe shortage of donor kidneys that are fit for transplantation, due in part to a lack of adequate viability assessment tools for transplant organs. This work presents the integration of a novel wireless two-channel amperometr
Autor:
Isabelle C, Samper, Sally A N, Gowers, Michelle L, Rogers, De-Shaine R K, Murray, Sharon L, Jewell, Clemens, Pahl, Anthony J, Strong, Martyn G, Boutelle
Publikováno v:
Lab on a chip. 19(11)
This paper presents the design, optimisation and fabrication of a mechanically robust 3D printed microfluidic device for the high time resolution online analysis of biomarkers in a microdialysate stream at microlitre per minute flow rates. The device
Autor:
Danny O'Hare, Sally A. N. Gowers, Timothy M. Rawson, Mark Gilchrist, Mark Bayliss, Anthony E. G. Cass, Pantelis Georgiou, Alasdair P. MacGowan, Alison Holmes, Sanjiv Sharma, Mathew Kyriakides, David M.E. Freeman, Richard C Wilson, Andrew M. Lovering
Publikováno v:
The Lancet: Digital Health, Vol 1, Iss 7, Pp e335-e343 (2019)
e343
e335
e343
e335
Summary Background Enhanced methods of drug monitoring are required to support the individualisation of antibiotic dosing. We report the first-in-human evaluation of real-time phenoxymethylpenicillin monitoring using a minimally invasive microneedle-
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::29e1340b90935861b9916a742f6adae0
https://cronfa.swan.ac.uk/Record/cronfa51460/Download/51460__15498__66910aefae77417b8b6482c0441d71b4.pdf
https://cronfa.swan.ac.uk/Record/cronfa51460/Download/51460__15498__66910aefae77417b8b6482c0441d71b4.pdf
Autor:
Guang-Zhong Yang, Vincenzo F. Curto, Pankaj Vadgama, Martyn G. Boutelle, Carlo A. Seneci, Salzitsa Anastasova, Chu Wang, Sally A. N. Gowers
Publikováno v:
Analytical Chemistry
This work presents the design, fabrication, and characterization of a robust 3D printed microfluidic analysis system that integrates with FDA-approved clinical microdialysis probes for continuous monitoring of human tissue metabolite levels. The micr