Publikováno v:
Journal of ASTM International. 3:100365
Activity of templates (specimens), which were cut out from the inner surface of Kola-1 and Kola-2 WWER-440 reactor pressure vessels (RPVs), were measured, and the results were used to support the RPV dosimetry. Twelve weld and two base metal template
Publikováno v:
Journal of ASTM International. 3:13437
The commonly used method of WWER-1000 surveillance dosimetry is based on the measurement of 54Mn absolute activity in the material of surveillance specimens. Special procedures are necessary for the determination of the spectral index for each specim