Publikováno v:
Hepato-gastroenterology. 38(1)
A new catheter, provided with an Ion Sensitive Field Effect Transistor as a pH sensor and incorporating a reference electrode, was evaluated for esophageal pH recording. The pH-sensitivity was 54 mV/pH in vitro, with a linear response between pH 2 an
Publikováno v:
Scandinavian Journal of Clinical & Laboratory Investigation, 47(188), 31-35. Taylor & Francis Ltd
Since blood pH reflects the metabolic state as well as the functioning of the respiratory and circulatory systems, it appears to be one of the vital parameters that should be continuously monitored. The point to point measurement of pH by sampling ha
Publikováno v:
Ion Measurements in Physiology and Medicine ISBN: 9783540154686
Continuous monitoring of blood pH has a great potential for application in various clinical disciplines. Intravascular pH monitoring can be important in both diagnostic and therapeutic medicine. Cobbe and Poole-Wilson [5] have demonstrated that the p
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::66f7654d3822fc37827d4655b4c2060b
https://doi.org/10.1007/978-3-642-70518-2_44
https://doi.org/10.1007/978-3-642-70518-2_44
Publikováno v:
Critical care medicine. 14(9)
An arterial pH catheter was inserted into a femoral artery of 15 patients immediately after coronary artery bypass grafting. Catheter pH measurements correlated well with conventional blood gas measurements during the first 12 h postsurgery, and reve
Publikováno v:
Scandinavian journal of clinical and laboratory investigation. Supplementum. 188
Since blood pH reflects the metabolic state as well as the functioning of the respiratory and circulatory systems, it appears to be one of the vital parameters that should be continuously monitored. The point to point measurement of pH by sampling ha
Publikováno v:
Medicalbiological engineeringcomputing. 25(1)
In vivo tests were performed on a pH monitoring system. For this purpose 12 catheters were introduced into the arterial bloodstream of dogs. In the tip of the catheters (6F) a pH-sensitive ISFET sensor and an Ag/AgCl reference electrode were incorpor
Thein vivo stability and pH sensitivity of 19 intravascular pH electrodes for continuous monitoring have been investigated. The sensors were mounted in indwelling vascular catheters (7F) which were inserted into the arteries of seven anaesthetised an