Zobrazeno 1 - 10
of 64
pro vyhledávání: '"S. Benbarek"'
Publikováno v:
Frattura ed Integrità Strutturale, Vol 15, Iss 57, Pp 160-168 (2021)
People with trans-femoral amputation often experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in t
Externí odkaz:
https://doaj.org/article/290869922b214c6ebf1738c8b5c178ca
Publikováno v:
Frattura ed Integrità Strutturale, Vol 15, Iss 56, Pp 187-194 (2021)
The prosthetic liner plays a significant role in the redistribution of the pressure between the stump and the socket, as adds a cushioning layer between the stump and the socket which relieves pain and makes the prosthesis more comfortable.
Externí odkaz:
https://doaj.org/article/5e9e67fad8794d76a2b6528b3e71f875
Publikováno v:
Frattura ed Integrità Strutturale, Vol 15, Iss 57 (2021)
A lot of trans-femoral amputation patients experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in t
Externí odkaz:
https://doaj.org/article/0c9dce2066534a70a9b8a87bf8b87744
Publikováno v:
Frattura ed Integrità Strutturale, Vol 15, Iss 57, Pp 160-168 (2021)
Frattura ed Integrità Strutturale; Vol. 15 No. 57 (2021): July 2021; 160-168
Frattura ed Integrità Strutturale; V. 15 N. 57 (2021): July 2021; 160-168
Frattura ed Integrità Strutturale, Vol 15, Iss 57 (2021)
Frattura ed Integrità Strutturale; Vol. 15 No. 57 (2021): July 2021; 160-168
Frattura ed Integrità Strutturale; V. 15 N. 57 (2021): July 2021; 160-168
Frattura ed Integrità Strutturale, Vol 15, Iss 57 (2021)
A lot of trans-femoral amputation patients experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in t
Publikováno v:
Frattura ed Integrità Strutturale, Vol 15, Iss 56, Pp 187-194 (2021)
Frattura ed Integrità Strutturale; V. 15 N. 56 (2021): April 2021; 187-194
Frattura ed Integrità Strutturale; Vol. 15 No. 56 (2021): April 2021; 187-194
Frattura ed Integrità Strutturale; V. 15 N. 56 (2021): April 2021; 187-194
Frattura ed Integrità Strutturale; Vol. 15 No. 56 (2021): April 2021; 187-194
The prosthetic liner plays a significant role in the redistribution of the pressure between the stump and the socket, as it adding a cushioning layer between the stump and the socket which relieves pain and makes the prosthesis more comfortable. This
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Periodica Polytechnica Mechanical Engineering. 63:249-256
The finite element method is used to solve mechanical and physical problems in engineering analysis and design. Primary stability has been regarded as a prerequisite for osseointegration of dental implants. Biomechanical factors play a key role in th
Autor:
Mohammed El Sallah Zagane, Abderahmane Sahli, S. Benbarek, Abdelmadjid Moulgada, Ali Benouis, Mohamed Cherfi
Publikováno v:
Journal of the Serbian Society for Computational Mechanics. 12:96-107
Publikováno v:
Journal of Failure Analysis and Prevention. 18:1601-1606
The object of this study is an experimental analysis of the repair of a laminate composite damaged by central circular notch. The effects of the repair technique used, single or double patch, the nature of the patch and its stacking sequence, were hi
Publikováno v:
Composites Part B: Engineering. 142:102-107
Cohesive zone models (CZM) are widely used for modeling the damages interfacial. In this study, a three-dimensional finite element (FE) model is developed to study numerically the energy release rate (ERR) by the J integral method. The simulation of