Zobrazeno 1 - 10
of 32
pro vyhledávání: '"S Chiu-Tsao"'
Publikováno v:
Medical physics. 39(6Part11)
Purpose: To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x‐ray beams, with different spatial resolution.Methods: Two sets of EBT3 films (lot#A101711‐02) were exposed to each x‐ray be
Autor:
Maria F. Chan, S Chiu-Tsao
Publikováno v:
Medical Physics. 43:3597-3597
Purpose: To study the effect of film scanning orientation for new EBT-XD film using Vidar and Epson scanners, compared with EBT3 films. Methods: The EBT-XD (lot#01081501) and EBT3 films (lot#11031501) were cut into 4cm×7cm pieces and each film piece
Autor:
S. Chiu-Tsao
Publikováno v:
Medical Physics. 42:3626-3626
Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 publish
Autor:
S Chiu‐Tsao
Publikováno v:
Medical Physics. 36:2519-2520
Purpose: We developed an analytic expression and functional fitting scheme for the COMS eye plaque dosimetry data generated from Monte Carlo calculations which incorporated the heterogeneity effects of the COMS plaque assembly (gold alloy backing and
Autor:
S Chiu‐Tsao, Maria F. Chan
Publikováno v:
Medical Physics. 36:2604-2605
Purpose: We studied the dose response characteristics of the newly introduced EBT‐2 radiochromic films for megavoltage photon and electron beams of different energies. Method and Materials: EBT‐2 films (ISP prototype lot♯020609), 2.5×3.2cm2, w
Autor:
M Zaider, Dattatreyudu Nori, G Cohen, K. Chao, S Trichter, S Chiu‐Tsao, F Kulidzhanov, Albert Sabbas, J Chang
Publikováno v:
Medical Physics. 38:3791-3791
Purpose: The majority of eye plaques used in the U.S. are of Collaborative Ocular Melanoma Study (COMS) design with I‐125 brachytherapy seeds. Treatment planning is usually done using the TG‐43 formalism, not accounting for the gold alloy backing
Publikováno v:
Medical Physics. 36:2575-2575
Purpose: To evaluate the measured dose distributions using radiochromic EBT films and a 2D diode array as compared with treatment planning (TP) data at different gantry angles. Method and Materials: Radiochromic EBT films (ISP) were irradiated with 6
Autor:
S Chiu-Tsao, Maria F. Chan
Publikováno v:
Medical Physics. 35:2794-2794
Purpose: To measure the depth doses and profiles in the superficial buildup region for 6MV and 15MV photon beams using radiochromic EBT film stacks. Method and Materials: Eight radiochromic EBT film (lot♯35076) strips (3×20×0.024cm3) formed a sta
Autor:
M Chan, S Chiu-Tsao
Publikováno v:
Medical Physics. 34:2475-2475
Purpose: To study the feasibility of using new high sensitivity radiochromic film, GAFCHROMIC® Low Dose Film, in measuring the doses to off‐axis points for pacemaker. Method and Materials: Each experimental radiochromic film (ISP) was positioned a
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 54:19