Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Ryuzo Uehara"'
Publikováno v:
Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics. 42(2)
Autor:
Naoki Hayashi, Kensuke Tani, N Tohyama, Ryohei Miyasaka, Satoshi Kito, Yoshitaka Oka, Shunsuke Miyake, Hideki Kojima, Akihisa Wakita, Toru Takakura, Ryuzo Uehara, Yukio Fujita, Kazuya Shinoda, Norifumi Mizuno, Saito Yasunori
Publikováno v:
Medical physicsREFERENCES. 47(11)
PURPOSE The beam model in radiation treatment planning systems (RTPSs) plays a crucial role in determining the accuracy of calculated dose distributions. The purpose of this study was to ascertain differences in beam models and their dosimetric influ
Autor:
Ako Aikawa, Yukio Fujita, Takumi Kodama, Kensuke Tani, Akihisa Wakita, Jiro Kawamori, Hidetoshi Saitoh, Yuya Suzuki, Ryuzo Uehara, Ryohei Miyasaka, Norifumi Mizuno
Publikováno v:
Journal of Applied Clinical Medical Physics
In this study, the optimum density scaling factors of phantom materials for a commercially available three‐dimensional (3D) dose verification system (Delta4) were investigated in order to improve the accuracy of the calculated dose distributions in
Autor:
Ryuzo Uehara, Shinya Mizukami, Takuya Maeyama, Yusuke Watanabe, Tetsuo Akimoto, Hidenobu Tachibana, Tsuyoshi Terazaki
Publikováno v:
Brachytherapy. 19(3)
Purpose The purpose of this study was to develop a novel quality assurance (QA) program to check the entire treatment chain of image-guided brachytherapy with dose distribution evaluation in a single setup and irradiation using a gel dosimeter. Metho
Autor:
Tomoharu Sato, Fumiyasu Matsubayashi, Yasushi Ito, Ryuzo Uehara, Hidenobu Tachibana, Shinichi Yoshino
Publikováno v:
Japanese Journal of Radiological Technology. 69:617-631
It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry to
Autor:
Tomoharu Sato, Masaru Nakajima, Yasushi Ito, Masatoshi Hashimoto, Masahiko Oguchi, Yuko Sekiya, Takuyo Kozuka, Fumiyasu Matsubayashi, Ryo Takahashi, Nozomi Kitamura, S. Saotome, Ryuzo Uehara
Publikováno v:
Nihon Hoshasen Gijutsu Gakkai zasshi. 71(4)
When performing lung cancer treatments using volumetric modulated arc therapy (VMAT) technique, dose error related to respiratory motion of tumors and multi leaf collimator (MLC) movement may occur. The dose error causes daily dose variation in multi