Zobrazeno 1 - 10
of 37
pro vyhledávání: '"Ryouji Doihara"'
Autor:
Kar-Hooi Cheong, Noriyuki Furuichi, Ryouji Doihara, Shouta Kamazawa, Shigenori Kasai, Nobuko Hosobuchi
Publikováno v:
Measurement: Sensors, Vol 18, Iss , Pp 100321- (2021)
This paper presents a comparative evaluation study of a newly developed mass flowmeter which combines a positive-displacement volumetric flowmeter and a densitometer, comparing its performance with a well-established Coriolis mass flow metering techn
Externí odkaz:
https://doaj.org/article/2a8643ff5c034d09815d460f2eb25469
Autor:
Kar-Hooi Cheong, Ryouji Doihara, Noriyuki Furuichi, Masaharu Nakagawa, Ruriko Karasawa, Yoshihiro Kato, Kazunori Kageyama, Takuro Akasaka, Yuki Onuma, Takashi Kato
Publikováno v:
Applied Sciences, Vol 12, Iss 17, p 8421 (2022)
Intravenous (IV) fluid therapy is a common current medical practice, and the method has remained unchanged for more than a century. The IV bag is suspended from an IV stand or pole, and the pressure created by gravity is used to administer the drug.
Externí odkaz:
https://doaj.org/article/fd480f6f7a2e453e8859ee9d1f74c267
Publikováno v:
Journal of Fluid Science and Technology, Vol 2, Iss 1, Pp 23-34 (2007)
A new primary standard for hydrocarbon flow measurements has been constructed at National Metrology Institute of Japan (NMIJ). The facility was designed for the calibration of hydrocarbon flowmeters in the flow rate range between 3 and 300 m3/h. The
Externí odkaz:
https://doaj.org/article/680bebecc74d48f5a023979ce97ee4b1
Publikováno v:
Metrologia. 58:065003
Publikováno v:
Flow Measurement and Instrumentation. 81:102030
A static weighing system for a liquid microflow calibration rig, whose minimum flow rate is 1 mg/min (equivalent to 1 μL/min for water), was designed and evaluated. The developed weighing system, which can collect over 10 g of water, has two feature
Publikováno v:
Metrologia. 54:262-279
A flow calibration facility based on the gravimetric method using a double-wing diverter for hydrocarbon flows from 0.1 m3 h−1 to 15 m3 h−1 was constructed as a national measurement standard in Japan. The original working liquids were kerosene an
Publikováno v:
Flow Measurement and Instrumentation. 50:90-101
A calibration rig consisting of a syringe pump and a weighing tank system that can operate in the flow rate range of 0.02–60 L/h was developed in this study. This paper discusses the design considerations of the calibration methods, the development
Autor:
Shunsuke Akiguchi, Tomoaki Kyoden, Ryouji Doihara, Tsugunobu Andoh, Tomoki Tajiri, Tadashi Hachiga, Noriyuki Furuichi
Publikováno v:
Flow Measurement and Instrumentation. 70:101660
Multipoint laser Doppler velocimetry (MLDV) has been effective for non-invasively measuring the flow velocity distribution with a high-spatial and high-time resolution. The flow velocity can be estimated using a scattered light signal by seeding part
Publikováno v:
Flow Measurement and Instrumentation. 41:174-180
Several kinds of commercial flowmeters, namely, Coriolis flowmeters, turbine meters, ultrasonic flowmeters, and positive displacement flowmeters, have been calibrated using the primary standard for hydrocarbon flow measurement in Japan (which is base
Publikováno v:
The Proceedings of the Symposium on Micro-Nano Science and Technology. :21pm1PN314